Evidence map›Paper›PMID 33748075›Full record

ArticleFrontiers in chemistry2021

Microfluidic Flow Injection Immunoassay System for Algal Toxins Determination: A Case of Study.

Lorenzo Celio, Matteo Ottaviani, Rocco Cancelliere, Alessio Di Tinno, Peter Panjan, Adama Marie Sesay, Laura Micheli

Open access · goldAbstract read
In one paragraph

Article in Frontiers in chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
1.0field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 14 citations in OpenAlex.

  1. Review
  2. Review
  3. Article
  4. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 4 institutions in 3 countries.

Lorenzo CelioDepartement of Chemical Sciences and Technologies, University of Rome Tor Vergata, Rome, Italy.
Matteo OttavianiDepartment of Analytical Chemistry, University of Turin, Turin, Italy.
Rocco CancelliereDepartement of Chemical Sciences and Technologies, University of Rome Tor Vergata, Rome, Italy.
Alessio Di TinnoDepartement of Chemical Sciences and Technologies, University of Rome Tor Vergata, Rome, Italy.
Peter PanjanMeasurement Technology Research Unit, Oulu University, Kajaani, Finland.
Adama Marie SesayMeasurement Technology Research Unit, Oulu University, Kajaani, Finland.
Laura MicheliDepartement of Chemical Sciences and Technologies, University of Rome Tor Vergata, Rome, Italy.
University of Rome Tor Vergata · ITHarvard University · USKajaani University of Applied Sciences · FIUniversity of Turin · IT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

A novel flow injection microfluidic immunoassay system for continuous monitoring of saxitoxin, a lethal biotoxin, in seawater samples is presented in this article. The system consists of a preimmobilized G protein immunoaffinity column connected in line with a lab-on-chip setup. The detection of saxitoxin in seawater was carried out in two steps: an offline incubation step (competition reaction) performed between the analyte of interest (saxitoxin or Ag, as standard or seawater sample) and a tracer (an enzyme-conjugated antigen or Ag*) toward a specific polyclonal antibody. Then, the mixture was injected through a "loop" of a few μL using a six-way injection valve into a bioreactor, in line with the valve. The bioreactor consisted of a small glass column, manually filled with resin upon which G protein has been immobilized. When the mixture flowed through the bioreactor, all the antibody-antigen complex, formed during the competition step, is retained by the G protein. The tracer molecules that do not interact with the capture antibody and protein G are eluted out of the column, collected, and mixed with an enzymatic substrate directly within the microfluidic chip, via the use of two peristaltic pumps. When Ag* was present, a color change (absorbance variation, ΔAbs) of the solution is detected at a fixed wavelength (655 nm) by an optical chip docking system and registered by a computer. The amount of saxitoxin, present in the sample (or standard), that generates the variation of the intensity of the color, will be directly proportional to the concentration of the analyte in the analyzed solution. Indeed, the absorbance response increased proportionally to the enzymatic product and to the concentration of saxitoxin in the range of 3.5 × 10

Indexed as

algal toxinsFI-IAimmunoanalytical systemmicrochip flow-chamber systemsaxitoxin

Identifiers

PMID33748075
PMCPMC7974544
OpenAlexW3134632628

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.