Evidence map›Paper›PMID 33747718›Full record

ArticleAdvanced science (Weinheim, Baden-Wurttemberg, Germany)2021

Feasibility of a Dielectric Elastomer Augmented Aorta.

Morgan Almanza, Francesco Clavica, Jonathan Chavanne, David Moser, Dominik Obrist, Thierry Carrel, Yoan Civet, Yves Perriard

Abstract read
In one paragraph

Article in Advanced science (Weinheim, Baden-Wurttemberg, Germany), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Review
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Multilayer Dielectric Elastomer with Reconfigurable Electrodes for Artificial Muscle.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2023
    Article
  8. Article
  9. Article
  10. Article
  11. Feasibility of a Dielectric Elastomer Augmented Aorta.Advanced science (Weinheim, Baden-Wurttemberg, Germany) · 2021
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

Morgan AlmanzaIntegrated Actuators Laboratory École Polytechnique fédérale de Lausanne (EPFL) Neuchâtel 2000 Switzerland.ORCID https://orcid.org/0000-0002-3776-8633
Francesco ClavicaIntegrated Actuators Laboratory École Polytechnique fédérale de Lausanne (EPFL) Neuchâtel 2000 Switzerland.ORCID https://orcid.org/0000-0002-8967-5877
Jonathan ChavanneIntegrated Actuators Laboratory École Polytechnique fédérale de Lausanne (EPFL) Neuchâtel 2000 Switzerland.ORCID https://orcid.org/0000-0002-6976-1196
David MoserIntegrated Actuators Laboratory École Polytechnique fédérale de Lausanne (EPFL) Neuchâtel 2000 Switzerland.
Dominik ObristARTORG Center for Biomedical Engineering Research University of Bern Bern 3012 Switzerland.ORCID https://orcid.org/0000-0002-6062-9076
Thierry CarrelDepartment of Cardiovascular Surgery University Hospital and University of Bern Bern 3012 Switzerland.ORCID https://orcid.org/0000-0002-7881-6822
Yoan CivetIntegrated Actuators Laboratory École Polytechnique fédérale de Lausanne (EPFL) Neuchâtel 2000 Switzerland.ORCID https://orcid.org/0000-0002-7601-6223
Yves PerriardIntegrated Actuators Laboratory École Polytechnique fédérale de Lausanne (EPFL) Neuchâtel 2000 Switzerland.ORCID https://orcid.org/0000-0003-2350-4562

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Although heart transplantation is a gold standard for severe heart failure, there is a need for alternative effective therapies. A dielectric-elastomer aorta is used to augment the physiological role of the aorta in the human circulatory system. To this end, the authors developed a tubular dielectric elastomer actuator (DEA) able to assist the heart by easing the deformation of the aorta in the systole and by increasing its recoil force in the diastole. In vitro experiments using a pulsatile flow-loop, replicating human physiological flow and pressure conditions, show a reduction of 5.5% (47 mJ per cycle) of the heart energy with this device. Here, the controlled stiffness of the DEA graft, which is usually difficult to exploit for actuators, is perfectly matching the assistance principle. At the same time, the physiological aortic pressure is exploited to offer a prestretch to the DEA which otherwise would require an additional bulky pre-stretching system to reach high performances.

Indexed as

artificial musclesaugmented aortascardiac assist devicesdielectric elastomer actuators

Identifiers

PMID33747718
PMCPMC7967089

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.