ArticleIEEE sensors journal2021
Data-Driven Shape Sensing of a Surgical Continuum Manipulator Using an Uncalibrated Fiber Bragg Grating Sensor.
Article in IEEE sensors journal, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
12 citing papers in PubMed, 66 citations in OpenAlex.
- PALPABLE: enhanced bending stiffness and proprioception in soft actuators for laparoscopic palpation.Frontiers in robotics and AI · 2026Article
- Shape Sensing of Continuum Manipulators with Fiber Bragg Grating Sensor Arrays: Accounting for Actuator Velocity Effects.IEEE sensors journal · 2025Article
- Fiber-Optic Sensor Spectrum Noise Reduction Based on a Generative Adversarial Network.Sensors (Basel, Switzerland) · 2024Article
- A Novel Catheter Shape-Sensing Method Based on Deep Learning with a Multi-Core Optical Fiber.Sensors (Basel, Switzerland) · 2023Article
- Design and Fabrication of a Fiber Bragg Grating Shape Sensor for Shape Reconstruction of a Continuum Manipulator.IEEE sensors journal · 2023Article
- FOSS-Based Method for Thin-Walled Structure Deformation Perception and Shape Reconstruction.Micromachines · 2023Article
- Data-driven Shape Sensing of Continuum Dexterous Manipulators Using Embedded Capacitive Sensor.Proceedings of IEEE Sensors. IEEE International Conference on Sensors · 2023Article
- Deformation Monitoring and Shape Reconstruction of Flexible Planer Structures Based on FBG.Micromachines · 2022Article
- A Dexterous Robotic System for Autonomous Debridement of Osteolytic Bone Lesions in Confined Spaces: Human Cadaver Studies.IEEE transactions on robotics : a publication of the IEEE Robotics and Automation Society · 2022Article
- Fluoroscopic Navigation for a Surgical Robotic System Including a Continuum Manipulator.IEEE transactions on bio-medical engineering · 2022Article
- An Active Steering Hand-held Robotic System for Minimally Invasive Orthopaedic Surgery Using a Continuum Manipulator.IEEE robotics and automation letters · 2021Article
- Shape Reconstruction Processes for Interventional Application Devices: State of the Art, Progress, and Future Directions.Frontiers in robotics and AI · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
Abstract
This article proposes a data-driven learning-based approach for shape sensing and Distal-end Position Estimation (DPE) of a surgical Continuum Manipulator (CM) in constrained environments using Fiber Bragg Grating (FBG) sensors. The proposed approach uses only the sensory data from an unmodeled uncalibrated sensor embedded in the CM to estimate the shape and DPE. It serves as an alternate to the conventional mechanics-based sensor-model-dependent approach which relies on several sensor and CM geometrical assumptions. Unlike the conventional approach where the shape is reconstructed from proximal to distal end of the device, we propose a reversed approach where the distal-end position is estimated first and given this information, shape is then reconstructed from distal to proximal end. The proposed methodology yields more accurate DPE by avoiding accumulation of integration errors in conventional approaches. We study three data-driven models, namely a linear regression model, a Deep Neural Network (DNN), and a Temporal Neural Network (TNN) and compare DPE and shape reconstruction results. Additionally, we test both approaches (data-driven and model-dependent) against internal and external disturbances to the CM and its environment such as incorporation of flexible medical instruments into the CM and contacts with obstacles in taskspace. Using the data-driven (DNN) and model-dependent approaches, the following max absolute errors are observed for DPE: 0.78 mm and 2.45 mm in free bending motion, 0.11 mm and 3.20 mm with flexible instruments, and 1.22 mm and 3.19 mm with taskspace obstacles, indicating superior performance of the proposed data-driven approach compared to the conventional approaches.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.