Evidence map›Paper›PMID 33738597›Full record

ArticleEuropean radiology2021

Optimum diameter threshold for lung nodules at baseline lung cancer screening with low-dose chest CT: exploration of results from the Korean Lung Cancer Screening Project.

Eui Jin Hwang, Jin Mo Goo, Hyae Young Kim, Jaeyoun Yi, Yeol Kim

Abstract read
PubMed Publisher
In one paragraph

Article in European radiology, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers, 2 of them syntheses that pooled it.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed, 2 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 2 syntheses or guidelines pooled it.

  1. Pooled it
  2. Pooled it
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
  10. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Eui Jin HwangDepartment of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, 101 Daehak-ro, Jongno-gu, Seoul, 03080, South Korea.
Jin Mo GooDepartment of Radiology and Institute of Radiation Medicine, Seoul National University College of Medicine, 101 Daehak-ro, Jongno-gu, Seoul, 03080, South Korea. jmgoo@plaza.snu.ac.kr.ORCID http://orcid.org/0000-0003-1791-7942
Hyae Young KimDepartment of Radiology, National Cancer Center, Goyang, South Korea.
Jaeyoun YiCoreline Soft Inc., Seoul, South Korea.
Yeol KimNational Cancer Control Institute, National Cancer Center, Goyang, South Korea.

Funding

Ministry of Health and Welfare 1520230National Cancer Center 163110-1
6 · The paper itself

Abstract

objectivesTo explore the optimum diameter threshold for solid nodules to define positive results at baseline screening low-dose CT (LDCT) and to compare two-dimensional and volumetric measurement of lung nodules for the diagnosis of lung cancers.

methodsWe included consecutive participants from the Korean Lung Cancer Screening project between 2017 and 2018. The average transverse diameter and effective diameter (diameter of a sphere with the same volume) of lung nodules were measured by semi-automated segmentation. Diagnostic performances for lung cancers diagnosed within 1 year after LDCT were evaluated using area under receiver-operating characteristic curves (AUCs), sensitivities, and specificities, with diameter thresholds for solid nodules ranging from 6 to 10 mm. The reduction of unnecessary follow-up LDCTs and the diagnostic delay of lung cancers were estimated for each threshold.

resultsFifty-two lung cancers were diagnosed among 10,424 (10,141 men; median age 62 years) participants within 1 year after LDCT. Average transverse (0.980) and effective diameters (0.981) showed similar AUCs (p = .739). Elevating the average transverse diameter threshold from 6 to 9 mm resulted in a significantly increased specificity (91.7 to 96.7%, p < .001), a modest reduction in sensitivity (96.2 to 94.2%, p = .317), a 60.2% estimated reduction of unnecessary follow-up LDCTs, and a diagnostic delay in 1.9% of lung cancers. Elevating the threshold to 10 mm led to a significant reduction in sensitivity (86.5%, p = .025).

conclusionsElevating the diameter threshold for solid nodules from 6 to 9 mm may lead to a substantial reduction in unnecessary follow-up LDCTs with a small proportion of diagnostic delay of lung cancers. KEY POINTS: • Elevation of the diameter threshold for solid nodules from 6 to 9 mm can substantially reduce unnecessary follow-up LDCTs with a small proportion of diagnostic delay of lung cancers. • The average transverse and effective diameters of lung nodules showed similar performances for the prediction of a lung cancer diagnosis.

Indexed as

Early Detection of CancerLung NeoplasmsDelayed DiagnosisHumansLungMaleMiddle AgedRepublic of KoreaTomography, X-Ray ComputedEarly detection of cancerLung neoplasmsSensitivitySpecificityTomography, X-ray computed

Identifiers

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.