Evidence map›Paper›PMID 33738523›Full record

ArticleWorld journal of surgery2021

The Added Value of Technetium-99 m Sestamibi Scan in Patients with Primary Hyperparathyroidism and Positive Ultrasound.

T Yalon, M Neymark, A Rottenberg, L Appelbaum, D Assaf, Y Kluger, H Mazeh, M Mekel

Abstract read
PubMed Publisher
In one paragraph

Article in World journal of surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed
0.7field-weighted citation impact, top 32% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 7 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 4 institutions in 1 country.

T YalonDepartment of General and oncologic Surgery - Surgery C, Chaim Sheba Medical Center, Sackler Faculty of Medicine, Tel-Aviv University, Ramat Gan, Israel. talik.yalon@gmail.com.ORCID http://orcid.org/0000-0002-4860-3199
M NeymarkRambam-Health Care Campus, Haifa, Israel.
A RottenbergHadassah Hebrew-University Medical Center - Mount Scopus Campus, Jerusalem, Israel.
L AppelbaumHadassah Hebrew-University Medical Center - Mount Scopus Campus, Jerusalem, Israel.
D AssafDepartment of General and oncologic Surgery - Surgery C, Chaim Sheba Medical Center, Sackler Faculty of Medicine, Tel-Aviv University, Ramat Gan, Israel.
Y KlugerRambam-Health Care Campus, Haifa, Israel.
H MazehHadassah Hebrew-University Medical Center - Mount Scopus Campus, Jerusalem, Israel.
M MekelRambam-Health Care Campus, Haifa, Israel.
Hebrew University of Jerusalem · ILTechnion – Israel Institute of Technology · ILTel Aviv University · ILRambam Health Care Campus · IL

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundNeck ultrasound (US) and Technetium-99 m Sestamibi (MIBI) scan are the most commonly used imaging studies for preoperative localization of parathyroid adenomas. The aim of this study was to determine the added value of MIBI scan and its effect on the operative plan via a hypothetical model where a stepwise approach is conducted and MIBI is considered only after the ultrasound is evaluated.

methodsPatients who underwent parathyroidectomy for primary hyperparathyroidism (PHPT) between 2012 and 2019 at two tertiary centers were included. Data collected included demographic data, preoperative workup, operative findings and follow-up. The added value of MIBI scans was determined for patients with positive ultrasound.

resultsA total of 513 patients with positive US result and a MIBI scan were included. If a stepwise approach was conducted then MIBI scan would not change the operative plan in 492 (95.9%). Among the remaining 21 patients, MIBI scan would correctly change the ultrasound-based operative plan in only 12 (2.3%) patients, while incorrectly change the plan in 9 (1.8%), resulting in unnecessary exploration of the contralateral side. In patients with sonographic appearance of a parathyroid gland larger than 1.2 cm, MIBI scan would correctly change the operative plan in only 1 of the 287 (0.35%) patients.

conclusionsOur study suggests that the routine use of MIBI scans may have limited added value in patients with PHPT and a positive neck ultrasound, especially in those with adenoma size larger than 1.2 cm. Positive ultrasound alone may be sufficient for the preoperative localization of parathyroid disease.

Indexed as

Hyperparathyroidism, PrimaryParathyroid NeoplasmsHumansParathyroidectomyRadiopharmaceuticalsTechnetiumTechnetium Tc 99m SestamibiUltrasonographyRadiopharmaceuticalsTechnetiumTechnetium-99Technetium Tc 99m Sestamibi

Identifiers

PMID33738523
OpenAlexW3138237487

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.