Evidence map›Paper›PMID 33738312›Full record

ArticleOrthopaedic journal of sports medicine2021

Adjustable-Loop Devices Promote Graft Revascularization in the Femoral Tunnel After ACL Reconstruction: Comparison With Fixed-Loop Devices Using Magnetic Resonance Angiography.

Aguri Kamitani, Kunio Hara, Yuji Arai, Satoru Atsumi, Takeshi Takahashi, Shuji Nakagawa, Yuta Fuji, Hiroaki Inoue, Kenji Takahashi

Open access · goldAbstract read
In one paragraph

Article in Orthopaedic journal of sports medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
1.3field-weighted citation impact, top 22% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed, 6 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Review
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Aguri KamitaniDepartment of Orthopedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.
Kunio HaraDepartment of Orthopedics, Japan Community Heath Care Organization Kyoto Kuramaguchi Medical Center, Kyoto, Japan.
Yuji AraiDepartment of Sports and Para-Sports Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.
Satoru AtsumiDepartment of Orthopedics, Japan Community Heath Care Organization Kyoto Kuramaguchi Medical Center, Kyoto, Japan.
Takeshi TakahashiDepartment of Radiology, Kyoto Kuramaguchi Medical Center, Kyoto, Japan.
Shuji NakagawaDepartment of Sports and Para-Sports Medicine, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.
Yuta FujiDepartment of Orthopedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.
Hiroaki InoueDepartment of Orthopedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.
Kenji TakahashiDepartment of Orthopedics, Graduate School of Medical Science, Kyoto Prefectural University of Medicine, Kyoto, Japan.
Kyoto Prefectural University of Medicine · JPKyoto Medical Center · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundHamstring tendon grafts are usually fixed in anterior cruciate ligament (ACL) reconstruction using either an adjustable-loop device (ALD) or a fixed-loop device (FLD). The contact area between the graft and the tunnel wall is different between the 2 devices. PURPOSE: To determine using magnetic resonance angiography (MRA) whether ALD and FLD result in different blood flow of the graft in the femoral tunnel during the early postoperative period. STUDY

designCohort study; Level of evidence, 3.

methodsBetween 2008 and 2018, a total of 42 patients (17 men and 25 women) underwent MRA at 3 months after ACL reconstruction. All surgical procedures were performed using semitendinosus tendon autografts folded into 4 strands. Overall, 23 patients underwent the FLD procedure and 19 patients underwent the ALD procedure. The signal intensity of the superior portion of the graft in the femoral tunnel was evaluated using transverse MRA images perpendicular to the femoral tunnel axis.

resultsMRA images showed high signal intensity in the superior portion of the graft in the femoral tunnel in 94.7% and 60.9% of the ALD patients and FLD patients, respectively, a statistically significant difference (

conclusionMRA images at 3 months after surgery revealed that blood flow reached the superior end of the tendon graft in the femoral tunnel in more patients who underwent ACL reconstruction with an ALD compared with an FLD.

Indexed as

angiographyanterior cruciate ligament reconstructionblood flowfemurhamstring tendons

Identifiers

PMID33738312
PMCPMC7934042
OpenAlexW3134734291

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.