ArticleCureus2021
Ab-Externo Implantation of XEN Gel Stent for Refractory Steroid-Induced Glaucoma After Lamellar Keratoplasty.
Article in Cureus, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
4 citing papers in PubMed, 5 citations in OpenAlex.
- Sustained Intraocular Pressure Control After iStent InfiniteJournal of clinical medicine · 2026Article
- Efficacy and Safety of Open-Conjunctiva Ab Externo 63 µm vs. 45 µm XENJournal of clinical medicine · 2025Article
- Efficacy and Safety of Ab Externo Open Conjunctiva XENJournal of clinical medicine · 2025Article
- One-Year Real-World Outcomes of Ab-Externo Gel Stent Placement From the EXPAND Study.Journal of glaucoma · 2025Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The hazy corneal donor-recipient interface after corneal transplant may cause difficulties when implanting the XEN gel stent via ab-interno approach. We aim to describe XEN gel stent implantation via ab-externo approach in refractory steroid-induced glaucoma after corneal lamellar keratoplasty. Under local anaesthesia, the XEN injector needle was inserted 7 mm behind the limbus with the bevel facing up, directly beneath the conjunctiva and advanced to the marked 2.5 mm scleral entry wound. The needle then pierced the sclera until the needle tip was just visible in the anterior chamber (AC). The slider was pushed until the tip of the XEN stent was seen in the AC. The needle was slowly withdrawn while still pushing the slider to complete stent deployment. Subconjunctival Mitomycin C 0.01% (30 µg/0.3 mL) was then injected posterior to the bleb. Three eyes of three patients with steroid-induced glaucoma after lamellar keratoplasty underwent XEN gel stent implantation via ab-externo approach placed at the superotemporal quadrant. Pre-operatively, all patients had uncontrolled IOP between 30-45 mmHg despite maximum medications and selective laser trabeculoplasty. After XEN gel stent implantation, IOP ranged between 10-17 mmHg with one or two topical antiglaucoma at 12 months. Complications include hypotony maculopathy, stent migration and hyphaema, all of which were successfully managed. Corneal graft remained clear at 12 months. XEN gel stent implantation via ab-externo approach is able to achieve good intraocular pressure (IOP) control without compromising cornea graft in patients with steroid-induced glaucoma after lamellar keratoplasty at 12 months.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials