ArticleThe Indian journal of radiology & imaging
Safety profile of adenosine stress cardiac MRI in a tertiary hospital in India.
Article in The Indian journal of radiology & imaging. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
3 citing papers in PubMed, 5 citations in OpenAlex.
- Tolerability and efficacy of a reduced dose adenosine stress cardiac magnetic resonance protocol under general anesthesia in infants and children.Pediatric radiology · 2023Article
- Article
- Diagnostic value of myocardial stress detection based on feature tracking MRI in patients with acute myocardial infarction.Journal of thoracic disease · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCoronary artery disease (CAD) is a major cause of morbidity and mortality in India. Stress Cardiac Magnetic Resonance (CMR) using vasodilator agent is well established in assessing the functional significance of CAD. Adenosine is the preferred agent, but can have severe side effects including dyspnoea, chest pain, atrioventricular block or bronchospasm. The stress CMR examination is not routinely performed in many of the clinical imaging departments in India.
objectiveThe aim of this study was to establish safety of adenosine as a pharmacological stressor agent for CMR in a tertiary care radiology department in India.
methodsA review of all patients undergoing stress CMR in our institution from May 2018 to May 2019 was made. Records were reviewed to collect response parameters and documented adverse reactions.
resultsA total of 1057 patients underwent stress CMR during this period. No death, myocardial infarction or atrio-ventricular block related complications were seen. Transient hypotension was seen in 20 patients (1.8') with spontaneous recovery after stopping infusion. Chest pain and breathlessness severe enough to discontinue the scan were seen in 6 (0.5') and 10 (0.9') patients, respectively. All patients with breathlessness recovered on low flow oxygen therapy with three requiring bronchodilator. Out of six patients with chest pain, three had immediate relief with sublingual nitroglycerin, and three required hospital admission for unstable angina. Of the latter three, 1 underwent revascularization on the same day and other two later in the week.
conclusionStress CMR using adenosine in appropriately selected patients is a highly safe procedure with significant side effects seen in less than 1' of patients. Therefore, it is safe to perform stress CMR studies in a fully equipped and well-trained radiology department in India.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.