Evidence map›Paper›PMID 33730202›Full record

ArticleAnalytical and bioanalytical chemistry2021

Isotope pattern deconvolution as a successful alternative to calibration curve for application in wastewater-based epidemiology.

Jorge Pitarch-Motellón, Lubertus Bijlsma, Juan Vicente Sancho Llopis, Antoni F Roig-Navarro

Abstract read
In one paragraph

Article in Analytical and bioanalytical chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors.

Jorge Pitarch-MotellónResearch Institute for Pesticides and Water, Universitat Jaume I, Avda. Sos Baynat, s/n, 12071, Castelló, Spain.
Lubertus BijlsmaResearch Institute for Pesticides and Water, Universitat Jaume I, Avda. Sos Baynat, s/n, 12071, Castelló, Spain.
Juan Vicente Sancho LlopisResearch Institute for Pesticides and Water, Universitat Jaume I, Avda. Sos Baynat, s/n, 12071, Castelló, Spain.
Antoni F Roig-NavarroResearch Institute for Pesticides and Water, Universitat Jaume I, Avda. Sos Baynat, s/n, 12071, Castelló, Spain. roig@uji.es.ORCID http://orcid.org/0000-0001-6273-4956

Funding

Generalitat Valenciana, Spain Research group of excellence (PROMETEO II/2014/023
6 · The paper itself

Abstract

An isotope pattern deconvolution (IPD) quantification method has been applied for the determination of five substances (amphetamine, benzoylecgonine, cocaine, methamphetamine and MDMA) in wastewater for the application in wastewater-based epidemiology (WBE). A previously validated method that used a calibration curve for quantification was modified to apply IPD. The two approaches were compared in terms of analytical uncertainty in recovery studies of quality control samples, i.e. six wastewater samples from different geographical origins spiked at two concentration levels. Both methods were reliable as they passed (z-score < 2) in an interlaboratory exercise. After 60 individual determinations, IPD provided 11 results outside recovery limits (70-120%) while the previous method produced 31 adverse results. All mean values for IPD were accurate whereas 6 out of 10 results showed RSD values higher than 30% or recoveries outside limits when using the former method. Moreover, the calculated method bias for the latter doubles that of IPD, which, in turn, makes the combined uncertainty (u(c)) much higher. Consequently, a simple change of data treatment-IPD quantification methodology-resulted in a lower uncertainty of the estimated illicit drug concentration, one of the main steps contributing to the final uncertainty in the normalized daily drug consumption through WBE. The current study demonstrated that the employment of IPD can also be very interesting for future applications of WBE, especially when matrix effects are high, complicating accurate quantification. In addition, when a high number of samples and/or compounds need to be analysed, IPD is faster than calibration and, eventually, cost-effective when isotopically labelled internal standard is highly expensive.

Indexed as

CalibrationHumansIllicit DrugsIsotopesLimit of DetectionReference StandardsReproducibility of ResultsSubstance Abuse DetectionWastewaterWater Pollutants, ChemicalIllicit DrugsIsotopesWastewaterWater Pollutants, ChemicalCombined uncertaintyIllicit drugsIsotope dilutionIsotope pattern deconvolutionMass spectrometryWastewater analysis

Identifiers

PMID33730202
PMCPMC7966919

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked