In one paragraph

Article in Brazilian journal of medical and biological research = Revista brasileira de pesquisas medicas e biologicas, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed, 1 pooled it
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 1 synthesis or guideline pooled it.

  1. Pooled it
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors.

R C DinatoGrupo de Estudo em Desempenho Aeróbio, Escola de Educação Física e Esporte, Universidade de São Paulo, São Paulo, SP, Brasil.ORCID http://orcid.org/0000-0002-5986-2348
R CruzGrupo de Estudo em Desempenho Aeróbio, Escola de Educação Física e Esporte, Universidade de São Paulo, São Paulo, SP, Brasil.ORCID http://orcid.org/0000-0002-1308-5993
R A AzevedoGrupo de Estudo em Desempenho Aeróbio, Escola de Educação Física e Esporte, Universidade de São Paulo, São Paulo, SP, Brasil.ORCID http://orcid.org/0000-0002-0346-7007
J S HasegawaGrupo de Estudo em Desempenho Aeróbio, Escola de Educação Física e Esporte, Universidade de São Paulo, São Paulo, SP, Brasil.ORCID http://orcid.org/0000-0001-9887-0714
R G SilvaGrupo de Estudo em Desempenho Aeróbio, Escola de Educação Física e Esporte, Universidade de São Paulo, São Paulo, SP, Brasil.ORCID http://orcid.org/0000-0001-6553-7851
A P RibeiroDepartamento de Pós-Graduação em Ciências da Saúde, Laborátorio de Biomecânica e Reabilitação Musculoesquelética, Universidade de Santo Amaro, São Paulo, SP, Brasil.ORCID http://orcid.org/0000-0002-1061-3789
A E Lima-SilvaGrupo de Pesquisa em Performance Humana, Departamento Acadêmico de Educação Física, Universidade Tecnológica Federal do Paraná, Curitiba, PR, Brasil.ORCID http://orcid.org/0000-0002-0613-5104
R BertuzziGrupo de Estudo em Desempenho Aeróbio, Escola de Educação Física e Esporte, Universidade de São Paulo, São Paulo, SP, Brasil.ORCID http://orcid.org/0000-0002-0407-9620

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

The present study compared the effects of a footwear designed to enhance energy return (thermoplastic polyurethane, TPU) vs minimalist shoes on running economy (RE) and endurance performance. In this counterbalanced and crossover design study, 11 recreational male runners performed two submaximal constant-speed running tests and two 3-km time-trials with the two shoe models. Oxygen uptake was measured during submaximal constant-speed running tests in order to determine the RE at 12 km/h and oxygen cost of running (CTO2) at individual average speed sustained during the 3-km running time-trials wearing either of the two shoes. Our results revealed that RE was improved (2.4%) with TPU shoes compared with minimalist shoes (P=0.01). However, there was no significant difference for CTO2 (P=0.61) and running performance (P=0.52) comparing the TPU (710±60 s) and the minimalist (718±63 s) shoe models. These novel findings demonstrate that shoes with enhanced mechanical energy return (i.e. TPU) produced a lower energy cost of running at low (i.e., 12 km/h) but not at high speeds (i.e., average speed sustained during the 3-km running time-trial, ∼15 km/h), ultimately resulting in similar running performance compared to the minimalist shoe.

Indexed as

RunningBiomechanical PhenomenaCross-Over StudiesHumansMaleOxygen ConsumptionShoes

Identifiers

PMID33729393
PMCPMC7959157

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.