Tunable blood oxygenation in the vascular anatomy of a semi-anthropomorphic photoacoustic breast phantom.

Maura Dantuma, Saskia Kruitwagen, Javier Ortega-Julia, Rutger P Pompe van Meerdervoort, Srirang Manohar

Abstract read
In one paragraph

Article in Journal of biomedical optics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed.

  1. Article
  2. Review
  3. Review
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
  9. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Maura DantumaUniversity of Twente, Multi-Modality Medical Imaging, Techmed Centre, Enschede, The Netherlands.
Saskia KruitwagenUniversity of Twente, Multi-Modality Medical Imaging, Techmed Centre, Enschede, The Netherlands.
Javier Ortega-JuliaUniversity of Twente, Multi-Modality Medical Imaging, Techmed Centre, Enschede, The Netherlands.
Rutger P Pompe van MeerdervoortPA Imaging R&D B.V, Enschede, The Netherlands.
Srirang ManoharUniversity of Twente, Multi-Modality Medical Imaging, Techmed Centre, Enschede, The Netherlands.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

significanceRecovering accurate oxygenation estimations in the breast with quantitative photoacoustic tomography (QPAT) is not straightforward. Accurate light fluence models are required, but the unknown ground truth of the breast makes it difficult to validate them. Phantoms are often used for the validation, but most reported phantoms have a simple architecture. Fluence models developed in these simplistic objects are not accurate for application on the complex tissues of the breast.

aimWe present a sophisticated breast phantom platform for photoacoustic (PA) and ultrasound (US) imaging in general, and specifically for QPAT. The breast phantom is semi-anthropomorphic in distribution of optical and acoustic properties and contains wall-less channels with blood. APPROACH: 3D printing approaches are used to develop the solid 3D breast phantom from custom polyvinyl chloride plastisol formulations and additives for replicating the tissue optical and acoustic properties. A flow circuit was developed to flush the channels with bovine blood with a controlled oxygen saturation level. To showcase the phantom's functionality, PA measurements were performed on the phantom with two oxygenation levels. Image reconstructions with and without fluence compensation from Monte Carlo simulations were analyzed for the accuracy of oxygen saturation estimations.

resultsWe present design aspects of the phantom, demonstrate how it is developed, and present its breast-like appearance in PA and US imaging. The oxygen saturations were estimated in two regions of interest with and without using the fluence models. The fluence compensation positively influenced the SO2 estimations in all cases and confirmed that highly accurate fluence models are required to minimize estimation errors.

conclusionsThis phantom allows studies to be performed in PA in carefully controlled laboratory settings to validate approaches to recover both qualitative and quantitative features sought after in in-vivo studies. We believe that testing with phantoms of this complexity can streamline the transition of new PA technologies from the laboratory to studies in the clinic.

Indexed as

Photoacoustic TechniquesAnimalsCattleImage Processing, Computer-AssistedMonte Carlo MethodPhantoms, ImagingSpectrum Analysisbreast imagingbreast phantomMonte Carlo simulationsphotoacoustic tomographyquantitative photoacousticsstandardization

Identifiers

PMID33728828
PMCPMC7961914

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.