Trial reportJournal of clinical monitoring and computing2022
To compare clinical versus ultrasound assessment of correct placement of ProSeal Laryngeal mask airway (PLMA): a prospective randomized study.
Trial report in Journal of clinical monitoring and computing, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 1 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
Extraglottic airway devices (EAD) have revolutionized the perioperative airway management. The accuracy of clinical tests to identify malposition has been questioned by recent studies where fibreoptic evaluation identified various malpositions that were undiagnosed by a clinical test. Ultrasound (USG) has evolved to guide various airway interventions. However, USG is under-evaluated in the assessment of the EADs position. Our study aimed to compare clinical versus USG assessment of optimal placement of ProSeal laryngeal mask airway (PLMA). This randomized control trial was done in 212 consenting patients undergoing onco-surgery with PLMA as an airway device. Patients were randomized in Group CL (n-107) and US (n-105). Following primary assessment-using clinical tests and USG evaluation using a scoring system, fibreoptic evaluation of the placement of PLMA was done and then assessed for optimal position. The accuracy of each technique for optimal placement was compared statistically. We found that the sensitivity and specificity of the clinical evaluation were 98.77% and 34.62% with a diagnostic accuracy of 83.18% when compared with fibreoptic evaluation. While USG evaluation using the scoring system has sensitivity and specificity of 95.45% and 29.41% with a diagnostic accuracy of 84.76%. It was noted that USG assessment has a higher positive predictive value (87.5%) as compared to clinical assessment (82.47%). The incidence of rotation was higher in the clinical group. There was no difference in airway related morbidity. USG is comparable to clinical tests for evaluation of the optimal placement of PLMA. However, USG has various advantages over clinical assessment as it is quick and identifies the unacceptable placement of PLMA where the tip of PLMA may not lie over the tip of the esophagus, thereby, avoiding unnecessary mucosal injury during forceful or repeated attempts for gastric drainage tube insertion.Trial registration: Clinical Trials Registry (CTRI/2017/11/010359) dated 3rd November 2017.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.