Evidence map›Paper›PMID 33725219›Full record

Trial reportJournal of clinical monitoring and computing2022

To compare clinical versus ultrasound assessment of correct placement of ProSeal Laryngeal mask airway (PLMA): a prospective randomized study.

Kanika Rustagi, Rakesh Garg, Sachidanand Jee Bharti, Vinod Kumar, Nishkarsh Gupta, Seema Mishra, Sushma Bhatnagar

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Journal of clinical monitoring and computing, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.2field-weighted citation impact, top 48% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 1 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Kanika RustagiDepartment of Onco-Anaesthesia and Palliative Medicine, Dr BRAIRCH, All India Institute of Medical Sciences, Room No 139, First Floor, Ansari Nagar, New Delhi, 110029, India.
Rakesh GargDepartment of Onco-Anaesthesia and Palliative Medicine, Dr BRAIRCH, All India Institute of Medical Sciences, Room No 139, First Floor, Ansari Nagar, New Delhi, 110029, India. drrgarg@hotmail.com.ORCID 0000-0001-5842-8024
Sachidanand Jee BhartiDepartment of Onco-Anaesthesia and Palliative Medicine, Dr BRAIRCH, All India Institute of Medical Sciences, Room No 139, First Floor, Ansari Nagar, New Delhi, 110029, India.
Vinod KumarDepartment of Onco-Anaesthesia and Palliative Medicine, Dr BRAIRCH, All India Institute of Medical Sciences, Room No 139, First Floor, Ansari Nagar, New Delhi, 110029, India.
Nishkarsh GuptaDepartment of Onco-Anaesthesia and Palliative Medicine, Dr BRAIRCH, All India Institute of Medical Sciences, Room No 139, First Floor, Ansari Nagar, New Delhi, 110029, India.
Seema MishraDepartment of Onco-Anaesthesia and Palliative Medicine, Dr BRAIRCH, All India Institute of Medical Sciences, Room No 139, First Floor, Ansari Nagar, New Delhi, 110029, India.
Sushma BhatnagarDepartment of Onco-Anaesthesia and Palliative Medicine, Dr BRAIRCH, All India Institute of Medical Sciences, Room No 139, First Floor, Ansari Nagar, New Delhi, 110029, India.
All India Institute of Medical Sciences · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Extraglottic airway devices (EAD) have revolutionized the perioperative airway management. The accuracy of clinical tests to identify malposition has been questioned by recent studies where fibreoptic evaluation identified various malpositions that were undiagnosed by a clinical test. Ultrasound (USG) has evolved to guide various airway interventions. However, USG is under-evaluated in the assessment of the EADs position. Our study aimed to compare clinical versus USG assessment of optimal placement of ProSeal laryngeal mask airway (PLMA). This randomized control trial was done in 212 consenting patients undergoing onco-surgery with PLMA as an airway device. Patients were randomized in Group CL (n-107) and US (n-105). Following primary assessment-using clinical tests and USG evaluation using a scoring system, fibreoptic evaluation of the placement of PLMA was done and then assessed for optimal position. The accuracy of each technique for optimal placement was compared statistically. We found that the sensitivity and specificity of the clinical evaluation were 98.77% and 34.62% with a diagnostic accuracy of 83.18% when compared with fibreoptic evaluation. While USG evaluation using the scoring system has sensitivity and specificity of 95.45% and 29.41% with a diagnostic accuracy of 84.76%. It was noted that USG assessment has a higher positive predictive value (87.5%) as compared to clinical assessment (82.47%). The incidence of rotation was higher in the clinical group. There was no difference in airway related morbidity. USG is comparable to clinical tests for evaluation of the optimal placement of PLMA. However, USG has various advantages over clinical assessment as it is quick and identifies the unacceptable placement of PLMA where the tip of PLMA may not lie over the tip of the esophagus, thereby, avoiding unnecessary mucosal injury during forceful or repeated attempts for gastric drainage tube insertion.Trial registration: Clinical Trials Registry (CTRI/2017/11/010359) dated 3rd November 2017.

Indexed as

Laryngeal MasksFiber Optic TechnologyHumansProspective StudiesAirway managementLaryngeal masksOptimal placementProSeal LMAUltrasonography

Identifiers

PMID33725219
OpenAlexW3136657344

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked