Evidence map›Paper›PMID 33725163›Full record

ArticleHeart and vessels2021

Clinical utility of CorVue intrathoracic impedance alert with device-measured physical activity in predicting heart failure events.

Yasushi Wakabayashi, Masanori Kobayashi, Tomohide Ichikawa, Takashi Koyama, Hidetoshi Abe

Abstract read
PubMed Publisher
In one paragraph

Article in Heart and vessels, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
0.5field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 4 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Comparative Analysis of Physical Activity DetectedFrontiers in cardiovascular medicine · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Yasushi WakabayashiDepartment of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, Matsumoto City, Nagano, 390-8505, Japan. 99098yw@jichi.ac.jp.ORCID http://orcid.org/0000-0002-8545-6060
Masanori KobayashiDepartment of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, Matsumoto City, Nagano, 390-8505, Japan.
Tomohide IchikawaDepartment of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, Matsumoto City, Nagano, 390-8505, Japan.
Takashi KoyamaDepartment of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, Matsumoto City, Nagano, 390-8505, Japan.
Hidetoshi AbeDepartment of Cardiovascular Medicine, Matsumoto Kyoritsu Hospital, 9-26 Habaue, Matsumoto City, Nagano, 390-8505, Japan.
Matsumoto City Hospital · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Cardiac implantable electronic devices (CIEDs) offer heart failure (HF) diagnostic information, including intrathoracic impedance (ITI) or physical activity (PA). However, few studies have evaluated the utility of these parameters measured by CIEDs with CorVue algorithm. The purpose of this study was to investigate the relationship between ITI alerts triggered by the CorVue algorithm and HF development. We also examined the association between device-measured PA and ITI alerts associated with HF development. We retrospectively studied consecutive patients with CIEDs equipped with CorVue algorithm, which were implanted between June 1, 2011 and August 31, 2019. These patients were divided into two groups: patients with decreased ITI followed by the ITI alerts (ITI alert group) and those without the alerts (non-ITI alert group). There were 35 and 14 patients in the ITI and non-ITI alert groups, respectively. A total of 96 ITI alerts were observed. ITI alerts associated with HF development were observed in 21% (20/96); whereas, ITI alerts not associated with HF development were observed in 79% (76/96). Accurate device-measured PA was confirmed in 76 ITI alerts, which consisted of 30 alerts with lower PA and 46 alerts without lower PA. ITI alerts associated with HF development were observed in 30% (9/30) of the alerts with lower PA, whereas observed only in 6.5% (3/46) of the alerts without lower PA. In conclusion, the CorVue ITI alerts indicated a high false-positive rate. However, device-measured PA may be useful to determine whether ITI alerts are associated with HF development or not, which was attributed to the high negative predictive value.

Indexed as

Defibrillators, ImplantableHeart FailureCardiography, ImpedanceElectric ImpedanceExerciseHumansProspective StudiesRetrospective StudiesCardiac implantable electronic deviceCorVueDevice-measured physical activityHeart failureIntrathoracic impedance

Identifiers

PMID33725163
OpenAlexW3138666333

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.