SynthesisThe Cochrane database of systematic reviews2021
Electrical conductance for the detection of dental caries.
Synthesis in The Cochrane database of systematic reviews, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 1 synthesis or guideline pooled it, 13 citations in OpenAlex.
- Visual or visual-tactile examination to detect and inform the diagnosis of enamel caries.The Cochrane database of systematic reviews · 2021Pooled it
- Classification Algorithms for Early Tooth Demineralization Assessment by Impedance Spectroscopy.Sensors (Basel, Switzerland) · 2025Article
- Global Research Trends in the Detection and Diagnosis of Dental Caries: A Bibliometric Analysis.International dental journal · 2025Review
- Minimum intervention oral care: staging and grading dental carious lesions in clinical practice.British dental journal · 2024Article
- Caries lesions diagnosis with deep convolutional neural network in intraoral QLF images by handheld device.BMC oral health · 2024Article
- ORCA-EFCD consensus report on clinical recommendation for caries diagnosis. Paper I: caries lesion detection and depth assessment.Clinical oral investigations · 2024Article
- Use of Digital Diagnostic Aids for Initial Caries Detection: A Review.Dentistry journal · 2023Review
- Enamel Caries Detection and Diagnosis: An Analysis of Systematic Reviews.Journal of dental research · 2022Article
- The silent epidemic of common oral diseases among the Arab population: An emerging health problem.Journal of family medicine and primary care · 2021Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
7 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundCaries is one of the most prevalent, preventable conditions worldwide. A wide variety of management options are available at different thresholds of disease, ranging from non-operative preventive strategies such as improved oral hygiene, reduced sugar diet, and application of topical fluoride, to minimally invasive treatments for early lesions which are limited to enamel, through to selective removal and restoration for extensive lesions. The cornerstone of caries detection is a visual and tactile dental examination, however, an increasing array of methods of caries lesion detection have been proposed that could potentially support traditional methods of detection and diagnosis. Earlier identification of disease could afford patients the opportunity of less invasive treatment with less destruction of tooth tissue, reduce the need for treatment with aerosol-generating procedures, and potentially result in a reduced cost of care to the patient and to healthcare services.
objectivesOur primary objective was to determine the diagnostic accuracy of different electrical conductance devices for the detection and diagnosis of non-cavitated coronal dental caries in different populations (children, adolescents, and adults) and when tested against different reference standards. SEARCH
methodsCochrane Oral Health's Information Specialist undertook a search of the following databases: MEDLINE Ovid (1946 to 26 April 2019); Embase Ovid (1980 to 26 April 2019); US National Institutes of Health Ongoing Trials Register (ClinicalTrials.gov, to 26 April 2019); and the World Health Organization International Clinical Trials Registry Platform (to 26 April 2019). We studied reference lists as well as published systematic review articles. SELECTION CRITERIA: We included diagnostic accuracy studies that compared electrical conductance devices with a reference standard of histology or an enhanced visual examination. This included prospective studies that evaluated the diagnostic accuracy of single index tests and studies that directly compared two or more index tests. We included studies using previously extracted teeth or those that recruited participants with teeth believed to be sound or with early lesions limited to enamel. Studies that explicitly recruited participants with more advanced lesions that were obviously into dentine or frankly cavitated were excluded. DATA COLLECTION AND ANALYSIS: Two review authors extracted data independently using a piloted study data extraction form based on the Quality Assessment of Diagnostic Accuracy Studies 2 (QUADAS-2). Sensitivity and specificity with 95% confidence intervals (CIs) were reported for each study. This information was displayed as coupled forest plots, and plotted as summary receiver operating characteristic (SROC) plots, displaying the sensitivity-specificity points for each study. Due to variability in thresholds we estimated diagnostic accuracy using hierarchical summary receiver operating characteristic (HSROC) methods. MAIN
resultsWe included seven studies reporting a total of 719 tooth sites or surfaces, with an overall prevalence of the target condition of 73% (528 tooth sites or surfaces). The included studies evaluated two index tests: the electronic caries monitor (ECM) (four studies, 475 tooth surfaces) and CarieScan Pro (three studies, 244 tooth surfaces). Six studies used histology as the reference standard, one used an enhanced visual examination. No study was considered to be at low risk of bias across all four domains or low concern for applicability or both. All studies were at high (five studies) or unclear (two studies) risk of bias for the patient selection domain. We judged two studies to be at unclear risk of bias for the index test domain, and one study to be at high risk of bias for the reference standard and flow and timing domains. We judged three studies to be at low concern for applicability for patient selection, and all seven studies to be of low concern for reference standard and flow and timing domains. Studies were synthesised using a hierarchical method for meta-analysis. There was variability in the results of the individual studies, with sensitivities which ranged from 0.55 to 0.98 and specificities from 0 to 1.00. These extreme values of specificity may be explained by a low number of healthy tooth surfaces in the included samples. The diagnostic odds ratio (DOR) was 15.65 (95% CI 1.43 to 171.15), and indicative of the variability in the included studies. Through meta-regression we observed no meaningful difference in accuracy according to device type or dentition. Due to the small number of studies we were unable to formally investigate other potential sources of heterogeneity. We judged the certainty of the evidence as very low, and downgraded for risk of bias due to limitations in the design and conduct of the included studies, imprecision arising from the relatively small number of surfaces studied, and inconsistency due to the variability of results. AUTHORS'
conclusionsThe design and conduct of studies to determine the diagnostic accuracy of methods to detect and diagnose caries in situ is particularly challenging. The evidence base to support the detection and diagnosis of caries with electrical conductance devices is sparse. Newer electrical conductance devices show promise and further research at the enamel caries threshold using a robust study design to minimise bias is warranted. In terms of applicability, any future studies should be carried out in a clinical setting to provide a realistic assessment within the oral cavity where plaque, staining, and restorations can be problematic.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.