ArticleJournal of neurointerventional surgery2022
Bailout stentectomy of 47 self-expandable intracranial stents.
Article in Journal of neurointerventional surgery, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
9 citing papers in PubMed, 11 citations in OpenAlex.
- Acute and Chronic Cerebral Hypoperfusion After Flow-Diverter Placement: Is There a Role for Extra-Intracranial Bypass? A Case Series and Narrative Literature Review.Neurology international · 2026Article
- Comaneci stent-angioplasty for the optimization of inadequately deployed flow diverter stents.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2026Article
- Mastering the Maze: A Narrative Guide on Advanced Tips and Tricks for the Management of Complex Thrombectomy.Stroke (Hoboken, N.J.) · 2026Review
- Human placenta as a biological vascular model for endovascular training.Frontiers in neurology · 2026Article
- Rescue waffle cone technique for managing stent dislodgement into a target aneurysm.Journal of cerebrovascular and endovascular neurosurgery · 2025Article
- Mechanical Comaneci 17-stent angioplasty for a sub-optimally deployed flow-diverter stent.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2025Article
- Removal of errant coils using the Tigertriever-13.Journal of neurointerventional surgery · 2024Article
- LVIS EVO stent-through-balloon after hydrocoil embolization of intracranial aneurysms: One-year results.Interventional neuroradiology : journal of peritherapeutic neuroradiology, surgical procedures and related neurosciences · 2024Observational
- Stentectomy of a Balloon-Mounted Stent From Vertebrobasilar Circulation: A Technical Report and Literature Review.Cureus · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
6 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundSelf-expanding stents are increasingly being deployed for stent-assisted coiling or flow diversion of intracranial aneurysms. Complications related to stent misbehavior may arise, however, including lack of expansion, device displacement, or parent vessel thrombosis. We present our experience of various stent removal techniques (stentectomy) with a focus on technical and clinical outcomes.
methodsStentectomy was attempted either with a single device, including the Alligator, Microsnare, or Solitaire, or by combining a Microsnare with a second device. Dual techniques included in this report are the Snare-over-Stentretriever technique we developed using a Microsnare and a Solitaire, and the previously described Loop-and-Snare technique using a Microsnare and a microwire. The technical success and complication rate, as well as the clinical outcome using the mRS were analyzed.
resultsForty-seven stentectomies were attempted in 36 patients treated for 37 aneurysms. Forty-two devices (89.3%) were successfully retrieved. Single-device stentectomy was successful in 34% of cases, compared with 74% with dual-device techniques. Of the 20 patients with a thrombosed parent or efferent vessel, 17 were successfully recanalized using stentectomy. All successful stentectomy patients made a clinically uneventful recovery, except one with a minor postoperative stroke (mRS 1 at discharge). Failed stentectomy was associated with major ischemic stroke in two patients and death in one patient. There were no stentectomy-related vessel perforations or dissections.
conclusionWhile various single devices can be used to safely retrieve dysfunctional intracranial self-expandable stents, dual-device techniques are more than twice as effective, according to our experience.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.