ArticleSurgical endoscopy2021
Prevention of non-recurrent laryngeal nerve injury in robotic thyroidectomy: imaging and technique.
Article in Surgical endoscopy, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 10 citations in OpenAlex.
- Preoperative CT diagnosis of aberrant right subclavian artery and prediction of a nonrecurrent laryngeal nerve: a case report.International journal of surgery case reports · 2026Article
- Intraoperative identification of a left non-recurrent laryngeal nerve by neuromonitoring: a critical anatomical finding-case report.Journal of surgical case reports · 2026Article
- Detailed analysis of learning phases and outcomes in robotic and endoscopic thyroidectomy.Surgical endoscopy · 2024Article
- Modern Surgical Techniques of Thyroidectomy and Advances in the Prevention and Treatment of Perioperative Complications.Cancers · 2023Review
- Non-recurrent right laryngeal nerve identified during endoscopic thyroidectomy via areolar approach: a case report.Frontiers in surgery · 2023Article
- Abu Dhabi Neural Mapping (ADNM) during Minimally Invasive Thyroidectomy Enables the Early Identification of Non-Recurrent Laryngeal Nerve and Prevents Voice Dysfunction.Journal of clinical medicine · 2022Article
- Robotic bilateral axillo-breast versus endoscopic bilateral areola thyroidectomy outcomes of 757 patients.Frontiers in endocrinology · 2022Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
9 authors at 3 institutions in 3 countries.
Funding
No grant is acknowledged in the PubMed record.
Abstract
introductionThe aim of this report was to summarize observations, evaluate the feasibility, provide detailed information concerning proper techniques, and address limitations for non-recurrent laryngeal nerve (NRLN) dissection and release during the robotic bilateral axillo-breast approach (BABA) for thyroidectomy. MATERIALS AND
methodsThe BABA approach was used in two cases of thyroidectomy in the setting of NRLN. Preoperative CT imaging findings suggesting the aberrant anatomy are reviewed and technical planning, inclusive of intraoperative nerve monitoring, was employed. Intraoperative videos with narrative discussion of technique for safe dissection are provided, along with supplementary video of additional technical guidance.
resultsIn both cases, the NRLNs were identified, dissected, and preserved. We dissected the proximal segment of each NRLN to its origin. We determined that the use of only the NRLN proximal to distal robotic dissection jeopardized the nerve. The BABA approach with the Type I NRLN is similar to the dissection of the recurrent laryngeal nerve (RLN) in transoral thyroidectomy. Due to interference with endoscopic viewing caused by the thyroid cartilage, the Type I NRLN is more challenging to manage both at the laryngeal entry point and its origin from the vagus nerve (VN). For the Type II NRLN, it is essential to identify its point of origin and the reflection of the nerve from the VN. Therefore, modification of nerve dissection to mirror open surgery with bidirectional nerve dissection assisted in avoidance of traction injury to the nerve.
conclusionsWe presented a video, a detailed description of methods, and discussed limits for NRLN management in robotic BABA. This report included (i) a description of the aberrant anatomy and CT scans to inform surgeons of the possible NRLN locations, (ii) a description of a technique for using the nerve monitor in the robotic surgeries, and (iii) a description of the techniques used to isolate and protect the NRLN during the robotic surgery. In robotic BABA, our NRLN-sparing technique and degree included mainly a multi-directional nerve dissection (i.e., medial-grade, later-grade approach together with proximal to/from distal) using athermal technique. The NRLN-sparing technique is predominantly carried out in an anterior dissection plane.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.