Evidence map›Paper›PMID 33719675›Full record

ArticleJournal of feline medicine and surgery2021

Quantitative assessment of infusion pump-mediated haemolysis in feline packed red blood cell transfusions.

Carles Blasi-Brugué, Ignacio M Sanchez, Rui Rf Ferreira, Augusto Jf de Matos, Rafael Ruiz de Gopegui

Open access · greenAbstract read
In one paragraph

Article in Journal of feline medicine and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.1field-weighted citation impact, top 71% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 2 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 3 institutions in 2 countries.

Carles Blasi-BruguéDepartment of Animal Medicine and Surgery, Veterinary Faculty, Autonomous University of Barcelona, Barcelona, Spain.ORCID 0000-0002-8750-2016
Ignacio M SanchezAnimal Blood Bank, Barcelona, Spain.
Rui Rf FerreiraAnimal Blood Bank, Barcelona, Spain.
Augusto Jf de MatosAnimal Science and Study Centre, Food and Agrarian Sciences and Technologies Institute, University of Porto, Porto, Portugal.
Rafael Ruiz de GopeguiDepartment of Animal Medicine and Surgery, Veterinary Faculty, Autonomous University of Barcelona, Barcelona, Spain.
Banc de Sang i Teixits · ESUniversitat Autònoma de Barcelona · ESUniversidade do Porto · PT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectivesHaemolysis caused by the use of peristaltic infusion pumps (PIPs) has been described in human and canine packed red blood cells (pRBCs). The aim of this study was to evaluate the effects of two different linear PIPs on the haemolysis of feline pRBC units stored for a long time.

methodsFeline pRBC units stored with adenine, dextrose, mannitol and sodium chloride (SAGM) were manufactured. After 35-42 days of storage at 2-4°C, a line administration system with a 180 µm filter was attached to every pRBC bag, the system was drained by gravity alone (8 drops/min) and a 1.3 ml sample was collected (G). A NIKI V4 pump was then used at a flow rate of 25 ml/h, the flow was stopped when the infusion system was filled with blood coming from the infusion pump and another 1.3 ml sample was collected (NK). Finally, an Infusomat FmS pump was evaluated, collecting another 1.3 ml sample (IM). Packed cell volume (PCV) was measured in all samples by microhaematocrit centrifugation, total haemoglobin (HGB) was measured using a specific haemoglobin analyser and, after centrifugation, free HGB was determined by spectrophotometry. The percentage of haemolysis was calculated. Friedman's test was used to compare the samples.

resultsFifteen feline pRBC units were evaluated. The average degree of haemolysis for sample G (gravity-assisted) was 1.12%. Comparison of the degree of gravity-assisted haemolysis with haemolysis in PIP NK (1.13%) and IM (1.14%) samples revealed no significant differences, with differences of only 0.01% and 0.02%, respectively. CONCLUSIONS AND RELEVANCE: The results of this study demonstrate that the use of two common PIPs in veterinary hospitals does not produce levels of haemolysis that are significantly different than that caused by gravity alone during transfusion of feline pRBCs at a rate of 25 ml/h.

Indexed as

Cat DiseasesDog DiseasesAnimalsBlood PreservationCatsDogsErythrocytesErythrocyte TransfusionHematocritHemolysisInfusion Pumpsbloodhaemolysisinfusion pumpInfusomat FmSNIKI V4pRBCTransfusion

Identifiers

PMID33719675
PMCPMC10812153
OpenAlexW3139128165

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.