Evidence map›Paper›PMID 33719135›Full record

ArticleAnnals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc2021

Artificial intelligence for detecting electrolyte imbalance using electrocardiography.

Joon-Myoung Kwon, Min-Seung Jung, Kyung-Hee Kim, Yong-Yeon Jo, Jae-Hyun Shin, Yong-Hyeon Cho, Yoon-Ji Lee, Jang-Hyeon Ban, Ki-Hyun Jeon, Soo Youn Lee and 2 more

Open access · goldAbstract readMulticenter Study
In one paragraph

Article in Annals of noninvasive electrocardiology : the official journal of the International Society for Holter and Noninvasive Electrocardiology, Inc, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 32 papers.

0numbers the graph read from it
0cells of the map it votes in
32citing papers in PubMed
7.0field-weighted citation impact, top 2% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

32 citing papers in PubMed, 61 citations in OpenAlex.

  1. Review
  2. Article
  3. Review
  4. Review
  5. Article
  6. Article
  7. Review
  8. Article
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Article
  16. Article
  17. Article
  18. Review
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors at 3 institutions in 1 country.

Joon-Myoung KwonMedical Research Team, Medical AI Co. Ltd., Seoul, South Korea.ORCID 0000-0001-6754-1010
Min-Seung JungMedical Research Team, Medical AI Co. Ltd., Seoul, South Korea.
Kyung-Hee KimArtificial Intelligence and Big Data Research Center, Sejong Medical Research Institute, Bucheon, South Korea.
Yong-Yeon JoMedical Research Team, Medical AI Co. Ltd., Seoul, South Korea.
Jae-Hyun ShinMedical Research Team, Medical AI Co. Ltd., Seoul, South Korea.
Yong-Hyeon ChoMedical Research Team, Medical AI Co. Ltd., Seoul, South Korea.
Yoon-Ji LeeMedical Research Team, Medical AI Co. Ltd., Seoul, South Korea.
Jang-Hyeon BanMedical R&D Center, Bodyfriend Co. Ltd., Seoul, South Korea.
Ki-Hyun JeonArtificial Intelligence and Big Data Research Center, Sejong Medical Research Institute, Bucheon, South Korea.
Soo Youn LeeArtificial Intelligence and Big Data Research Center, Sejong Medical Research Institute, Bucheon, South Korea.
Jinsik ParkDivision of Cardiology Cardiovascular Center, Mediplex Sejong Hospital, Incheon, South Korea.
Byung-Hee OhDivision of Cardiology Cardiovascular Center, Mediplex Sejong Hospital, Incheon, South Korea.
Seoul Medical Center · KRSejong Institute · KRSejong General Hospital · KR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

introductionThe detection and monitoring of electrolyte imbalance is essential for appropriate management of many metabolic diseases; however, there is no tool that detects such imbalances reliably and noninvasively. In this study, we developed a deep learning model (DLM) using electrocardiography (ECG) for detecting electrolyte imbalance and validated its performance in a multicenter study. METHODS AND

resultsThis retrospective cohort study included two hospitals: 92,140 patients who underwent a laboratory electrolyte examination and an ECG within 30 min were included in this study. A DLM was developed using 83,449 ECGs of 48,356 patients; the internal validation included 12,091 ECGs of 12,091 patients. We conducted an external validation with 31,693 ECGs of 31,693 patients from another hospital, and the result was electrolyte imbalance detection. During internal, the area under the receiving operating characteristic curve (AUC) of a DLM using a 12-lead ECG for detecting hyperkalemia, hypokalemia, hypernatremia, hyponatremia, hypercalcemia, and hypocalcemia were 0.945, 0.866, 0.944, 0.885, 0.905, and 0.901, respectively. The values during external validation of the AUC of hyperkalemia, hypokalemia, hypernatremia, hyponatremia, hypercalcemia, and hypocalcemia were 0.873, 0.857, 0.839, 0.856, 0.831, and 0.813 respectively. The DLM helped to visualize the important ECG region for detecting each electrolyte imbalance, and it showed how the P wave, QRS complex, or T wave differs in importance in detecting each electrolyte imbalance.

conclusionThe proposed DLM demonstrated high performance in detecting electrolyte imbalance. These results suggest that a DLM can be used for detecting and monitoring electrolyte imbalance using ECG on a daily basis.

Indexed as

Artificial IntelligenceCohort StudiesElectrocardiographyFemaleHumansMaleMiddle AgedReproducibility of ResultsRetrospective StudiesWater-Electrolyte Imbalanceartificial intelligencedeep learningelectrocardiographyelectrolytes

Identifiers

PMID33719135
PMCPMC8164149
OpenAlexW3136766298

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.