Evidence map›Paper›PMID 33715632›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2021

Safety and image quality of cardiovascular magnetic resonance imaging in patients with retained epicardial pacing wires after heart transplantation.

Constantin Gatterer, Marie-Elisabeth Stelzmüller, Andreas Kammerlander, Andreas Zuckermann, Martin Krššák, Christian Loewe, Dietrich Beitzke

Open access · goldAbstract read
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 1 institution in 1 country.

Constantin GattererDepartment of Biomedical Imaging and Image-guided Therapy, Division of Cardiovascular and Interventional Radiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.ORCID 0000-0003-1029-085X
Marie-Elisabeth StelzmüllerDepartment of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria.ORCID 0000-0002-1469-7211
Andreas KammerlanderDepartment of Medicine II, Division of Cardiology, Medical University of Vienna, Vienna, Austria.ORCID 0000-0002-7632-9879
Andreas ZuckermannDepartment of Surgery, Division of Cardiac Surgery, Medical University of Vienna, Vienna, Austria.ORCID 0000-0002-8054-8150
Martin KrššákDepartment of Medicine III, Division of Endocrinology and Metabolism, Medical University of Vienna, Vienna, Austria.ORCID 0000-0001-9717-803X
Christian LoeweDepartment of Biomedical Imaging and Image-guided Therapy, Division of Cardiovascular and Interventional Radiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria.ORCID 0000-0003-2502-0676
Dietrich BeitzkeDepartment of Biomedical Imaging and Image-guided Therapy, Division of Cardiovascular and Interventional Radiology, Medical University of Vienna, Währinger Gürtel 18-20, 1090, Vienna, Austria. dietrich.beitzke@meduniwien.ac.at.ORCID 0000-0003-3179-3827
Medical University of Vienna · AT

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundTemporary epicardial pacing wires, implemented in patients during heart transplantation, are routinely removed before discharge. However, in some cases, these wires may remain in situ and are often considered as a contraindication for cardiovascular magnetic resonance (CMR) imaging in the future. Therefore, we aimed to provide data about safety and image quality of CMR in these patients.

methodsThis is a report on a subpopulation out of 88 patients after heart transplantation that were included in a prospective cohort study and underwent multiple CMR in their post-transplant course. During CMR, patients were monitored by electrocardiogram and all examinations were observed by a physician to document potential adverse events. Additionally, image quality was assessed by an imaging specialist.

resultsNineteen of 88 patients included had temporary pacing wires in situ. These patients underwent a total of 51 CMR studies. No major adverse event and only one single, mild sensory event could be documented. All CMR studies showed preserved diagnostic image quality. Temporary pacing wires were visible in 100% of HASTE and cine sequences. In less than 50% of the examinations, temporary pacing wires were also visible in T1 and T2 mapping, short tau inversion recovery (STIR), and late gadolinium enhancement (LGE) sequences, without any impairment of image quality.

conclusionsWith a low event rate of only one mild adverse event during 51 CMR examinations (2%), CMR appears to be safe in patients with retained temporary epicardial pacing wires after heart transplantation. Moreover, image quality was not impaired by the presence of pacing wires.

Indexed as

Cardiac Pacing, ArtificialHeart TransplantationMagnetic Resonance ImagingPacemaker, ArtificialAdultAgedElectrocardiographyFemaleHumansMaleMiddle AgedPredictive Value of TestsProspective StudiesRisk AssessmentRisk FactorsTime FactorsCardiac transplantationCardiovascular magnetic resonanceImage qualityMR safety

Identifiers

PMID33715632
PMCPMC7962314
OpenAlexW3137107171

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.