Evidence map›Paper›PMID 33715056›Full record

Trial reportKnee surgery, sports traumatology, arthroscopy : official journal of the ESSKA2022

The technique of cement application has no influence on cement intrusion in total knee arthroplasty: randomized study comparing three different techniques.

Pedro Hinarejos, Albert Fontanellas, Joan Leal-Blanquet, Juan Sánchez-Soler, Raul Torres-Claramunt, Juan Carlos Monllau

Abstract readRandomized Controlled Trial
PubMed Publisher
In one paragraph

Trial report in Knee surgery, sports traumatology, arthroscopy : official journal of the ESSKA, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.6field-weighted citation impact, top 33% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 3 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 3 institutions in 1 country.

Pedro HinarejosDepartment of Orthopedic Surgery, Parc de Salut Mar, Hospital de l'Esperança, Sant Josep de la Muntanya, 12, 08024, Barcelona, Spain. Phinarejos@parcdesalutmar.cat.ORCID http://orcid.org/0000-0001-7567-1317
Albert FontanellasDepartment of Orthopedic Surgery, Parc de Salut Mar, Hospital de l'Esperança, Sant Josep de la Muntanya, 12, 08024, Barcelona, Spain.
Joan Leal-BlanquetDepartment of Orthopedic Surgery, Hospital d'Igualada, Consorci Sanitari de l'Anoia, Av. Catalunya, 11, 08700, Igualada, Barcelona, Spain.
Juan Sánchez-SolerDepartment of Orthopedic Surgery, Parc de Salut Mar, Hospital de l'Esperança, Sant Josep de la Muntanya, 12, 08024, Barcelona, Spain.
Raul Torres-ClaramuntDepartment of Orthopedic Surgery, Parc de Salut Mar, Hospital de l'Esperança, Sant Josep de la Muntanya, 12, 08024, Barcelona, Spain.
Juan Carlos MonllauDepartment of Orthopedic Surgery, Parc de Salut Mar, Hospital de l'Esperança, Sant Josep de la Muntanya, 12, 08024, Barcelona, Spain.
Universitat Autònoma de Barcelona · ESHospital de l'Esperança · ESHospital d'Igualada · ES

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeThe aim of the study was to compare the distance of intrusion of the cement into the bone in different areas both in the femur and the tibia in vivo, measured in the radiograph after implanting a total knee arthroplasty (TKA) with three different cement techniques.

methodsA prospective randomized study of 90 consecutive patients operated on at our institution with a cemented U2 Knee System TKA and medium viscosity Simplex P

resultsThe average intrusion of the cement was similar in all three groups of cementing techniques in the femoral components (1.6 mm; p = 0.386), and in the tibial components (2.6 mm; p = 0.144). The intrusion of the cement in the tibia was greater in women than in men (p = 0.04). We used 21.1 (SD 5.8) g of cement in average. The amount of cement employed was greater when the cement was applied on both (implant and bone) surfaces (group 3: 24.03 g in average) than when it was applied only on the bone (group 1: 20.13 g; p = 0.01) or only on the implants (group 2: 19.20 g; p = 0.001). The amount of cement employed was greater in men than in women (p = 0.002) and it was also greater when a PS femoral component was used (p = 0.03). The amount of cement employed was directly correlated with the height of the patients (p = 0.01) and with the bigger size of the components (p < 0.001).

conclusionAll three cement application techniques have similar intrusion distance of the cement into the bone, and the intrusion depth of the cement into the trabecular tibial bone is greater than the minimum suggested for fixation.

Indexed as

Arthroplasty, Replacement, KneeKnee ProsthesisBone CementsCementationFemaleHumansMaleProspective StudiesTibiaBone CementsBone cementCement intrusionCement techniqueCement weightTotal knee arthroplasty

Identifiers

PMID33715056
OpenAlexW3136220190

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.