Evidence map›Paper›PMID 33712918›Full record

ArticleAnalytical and bioanalytical chemistry2021

Multiplex detection of blood-borne pathogens on a self-driven microfluidic chip using loop-mediated isothermal amplification.

Chunmei Xie, Shan Chen, Likun Zhang, Xiangpeng He, Yi Ma, Haiping Wu, Bingjie Zou, Guohua Zhou

Abstract read
PubMed Publisher
In one paragraph

Article in Analytical and bioanalytical chemistry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.0field-weighted citation impact, top 14% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 32 citations in OpenAlex.

  1. Article
  2. Lessons Learned from Liver-on-Chip Platform.Annals of biomedical engineering · 2025
    Review
  3. Review
  4. Review
  5. Article
  6. Review
  7. Review
  8. Review
  9. Article
  10. Review
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

8 authors at 3 institutions in 1 country.

Chunmei Xie *Department of Clinical Pharmacy, Jinling Hospital, Medical School of Nanjing University, Nanjing, 210002, Jiangsu, China.
Shan Chen *Department of Clinical Pharmacy, Jinling Hospital, Medical School of Nanjing University, Nanjing, 210002, Jiangsu, China.
Likun ZhangDepartment of Clinical Pharmacy, Jinling Hospital, Medical School of Nanjing University, Nanjing, 210002, Jiangsu, China.
Xiangpeng HeDepartment of Clinical Pharmacy, Jinling Hospital, Medical School of Nanjing University, Nanjing, 210002, Jiangsu, China.
Yi MaDepartment of Clinical Pharmacy, Jinling Hospital, Medical School of Nanjing University, Nanjing, 210002, Jiangsu, China.
Haiping WuDepartment of Clinical Pharmacy, Jinling Hospital, Medical School of Nanjing University, Nanjing, 210002, Jiangsu, China. 15952018065@126.com.
Bingjie ZouDepartment of Clinical Pharmacy, Jinling Hospital, Medical School of Nanjing University, Nanjing, 210002, Jiangsu, China. zbj523@163.com.
Guohua ZhouDepartment of Clinical Pharmacy, Jinling Hospital, Medical School of Nanjing University, Nanjing, 210002, Jiangsu, China. ghzhou@nju.edu.cn.
Nanjing University · CNNanjing Medical University · CNNanjing General Hospital of Nanjing Military Command · CN

Funding

Jiangsu Provincial Medical Youth Talent Program No. QNRC2016889Jiangsu Provincial Science Fund for Distinguished Young Scholars BK20180005National Natural Science Foundation of China 81673390
6 · The paper itself

Abstract

Detection of blood-borne pathogens such as hepatitis C virus (HCV), hepatitis B virus (HBV) and human immunodeficiency virus (HIV) is essential to ensure the safety of blood transfusion. However, traditional PCR-based pathogen nucleic acid detection methods require relatively high experimental facilities and are difficult to apply in areas with limited resources. In this study, a self-driven microfluidic chip was designed to carry out multiplex detection of HBV, HCV and HIV by using loop-mediated isothermal amplification (LAMP). Benefitting from the air permeability of the polydimethylsiloxane material, the chip could accomplish sample loading within 12 min driven by the pressure difference between the reaction chambers and vacuum chambers in the chip without using pumps or any injection devices. Multiplex detection is achieved by presetting LAMP primers specific to different targets in different reaction chambers. Calcein was used as an indicator to indicate the positive amplification reaction, and the result can be recorded by a smartphone camera. After 50 min of isothermal amplification at 63 °C, 2 copies/μL of HBV, HCV and HIV target nucleic acids could be detected. The results of HBV detection of 20 clinical plasma samples by using the chip are consistent with that of the qPCR-based kit, indicating that the LAMP-based self-driven chip has the clinical application potential for blood-borne pathogen detection, especially in resource-limited areas.

Indexed as

Lab-On-A-Chip DevicesBlood-Borne PathogensHepacivirusHepatitis B virusHIVLimit of DetectionMicrofluidic Analytical TechniquesMolecular Diagnostic TechniquesNucleic Acid Amplification TechniquesBlood-borne pathogensLoop-mediated isothermal amplificationMultiplex detectionSelf-driven microfluidic chip

Identifiers

PMID33712918
OpenAlexW3135224551

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.