ArticleJournal of the American Society of Echocardiography : official publication of the American Society of Echocardiography2021
Augmentation of Tissue Perfusion with Contrast Ultrasound: Influence of Three-Dimensional Beam Geometry and Conducted Vasodilation.
Article in Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 15 citations in OpenAlex.
- Ultrasound Cavitation of Microbubbles Augments Limb Perfusion and Promotes Ulcer Healing in Chronic Limb-Threatening Ischemia.JACC. Cardiovascular imaging · 2026Trial
- Influence of Microbubble Properties and Carrier Frequency on Ultrasound Cavitation-Induced Flow Augmentation.Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2026Article
- Influence of Atherosclerotic Risk Factors on the Effectiveness of Therapeutic Ultrasound Cavitation for Flow Augmentation.Journal of the American Society of Echocardiography : official publication of the American Society of Echocardiography · 2024Article
- Oxygen-loaded microbubble-mediated sonoperfusion and oxygenation for neuroprotection after ischemic stroke reperfusion.Biomaterials research · 2023Article
- Sono-assisted-thrombolysis by three-dimensional diagnostic ultrasound improves epicardial recanalization and microvascular perfusion in acute myocardial infarction.Quantitative imaging in medicine and surgery · 2022Article
- Augmentation of Pulmonary Perfusion by Conducted Effects of a Pulmonary Artery Ultrasound Catheter.Ultrasound in medicine & biology · 2022Article
- Contrast Ultrasound, Sonothrombolysis and Sonoperfusion in Cardiovascular Disease: Shifting to Theragnostic Clinical Trials.JACC. Cardiovascular imaging · 2022Review
Corrections and comments
- Commented on by
Authors and funding
8 authors at 2 institutions in 1 country.
Funding
Abstract
backgroundCavitation of microbubble contrast agents with ultrasound produces shear-mediated vasodilation and an increase in tissue perfusion. We investigated the influence of the size of the cavitation volume by comparing flow augmentation produced by two-dimensional (2D) versus three-dimensional (3D) therapeutic ultrasound. We also hypothesized that cavitation could augment flow beyond the ultrasound field through release of vasodilators that are carried downstream.
methodsIn 11 rhesus macaques, cavitation of intravenously administered lipid-shelled microbubbles was performed in the proximal forearm flexor muscles unilaterally for 10 min. Ultrasound cavitation (1.3 MHz, 1.5 MPa peak negative pressure) was performed with 2D or 3D transmission with beam elevations of 5 and 25 mm, respectively, and pulsing intervals (PIs) sufficient to allow complete postdestruction refill (5 and 12 sec for 2D and 3D, respectively). Contrast ultrasound perfusion imaging was performed before and after cavitation, using multiplane assessment within and beyond the cavitation field in 1.5-cm increments. Cavitation in the hindlimb of mice using 2D ultrasound at a PI of 1 or 5 sec was performed to examine microvascular flow changes from cavitation in only arteries versus the microcirculation.
resultsIn primates, the degree of muscle flow augmentation in the center of the cavitation field was similar for 2D and 3D conditions (five- to sixfold increase for both, P < .01 vs baseline). The spatial extent of flow augmentation was only modestly greater for 3D cavitation because of an increase in perfusion with 2D transmission that was detected outside of the cavitation field. In mice, cavitation in the microvascular compartment (PI 5 sec) produced the greatest degree of flow augmentation, yet cavitation in the arterial compartment (PI 1 sec) still produced a three- to fourfold increase in flow (P < .001 vs control). The mechanism for flow augmentation beyond the cavitation zone was investigated by in vitro studies that demonstrated cavitation-related release of vasodilators, including adenosine triphosphate and nitric oxide, from erythrocytes and endothelial cells.
conclusionsCompared with 2D transmission, 3D cavitation of microbubbles generates a similar degree of muscle flow augmentation, possibly because of a trade-off between volume of cavitation and PI, and only modestly increases the spatial extent of flow augmentation because of the ability of cavitation to produce conducted effects beyond the ultrasound field.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.