ArticleMedical & biological engineering & computing2021
Novel preclinical method for evaluating the efficacy of a percutaneous treatment in human ex vivo calcified plaque.
Article in Medical & biological engineering & computing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
0 citing papers in PubMed, 4 citations in OpenAlex.
No citing paper in PubMed yet.
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
4 authors at 1 institution in 1 country.
Funding
Abstract
The lack of suitable atherosclerotic calcification models and testing strategies inhibits preclinical efficacy testing of existing and novel percutaneous devices. The goal of this study is to develop a preclinical testing method for quantitatively and qualitatively evaluating the efficacy of noncompliant balloon angioplasty (NC BA) treatment in human ex vivo calcified plaque (CP). NC BA using a 3- and 4-mm diameter balloon was performed on an ex vivo tibial calcified vessel obtained from an amputation. Three-dimensional microcomputed tomography (μ-CT) imaging was performed pre- and post-BA to compare crack density in the CP. Comparing the pre- and posttreatment three-dimensional μ-CT images showed a glass-like cracking that occurred in the CP due to the BA procedure. Expansion of the 3-mm balloon showed little tissue deformation and no CP cracking. Although expansion of the 4-mm balloon occurred nonuniformly along balloon length and across the perpendicular projections, the balloon generated cracking throughout the CP, which allowed the surrounding elastic tissue to be dilated. This combined X-ray microscopy and μ-CT technique is a useful preclinical tool for quantifying the efficacy of percutaneous treatments for CP. Because of its nondestructive nature, the CP structure can be visualized pre- and posttreatment to determine the treatment effect.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.