Evidence map›Paper›PMID 33710527›Full record

ArticleMedical & biological engineering & computing2021

Novel preclinical method for evaluating the efficacy of a percutaneous treatment in human ex vivo calcified plaque.

Robert S Chisena, Jordan Sengenberger, Albert J Shih, Hitinder Gurm

Abstract read
PubMed Publisher
In one paragraph

Article in Medical & biological engineering & computing, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
0.8field-weighted citation impact, top 28% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 4 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 1 institution in 1 country.

Robert S ChisenaDepartment of Mechanical Engineering, University of Michigan at Ann Arbor, 2350 Hayward St, Ann Arbor, MI, 48109, USA. rchisena@umich.edu.ORCID http://orcid.org/0000-0002-0807-3947
Jordan SengenbergerDepartment of Biomedical Engineering, University of Michigan at Ann Arbor, 2200 Bonisteel Blvd, Ann Arbor, MI, 48109, USA.
Albert J ShihDepartment of Mechanical Engineering, University of Michigan at Ann Arbor, 2350 Hayward St, Ann Arbor, MI, 48109, USA.
Hitinder GurmDepartment of Internal Medicine, University of Michigan Health System at Ann Arbor, 1500 E Medical Center Dr, Ann Arbor, MI, 48109, USA.
University of Michigan · US

Funding

The Cleveland Clinic Innovation AcceleratorU54HL119810 · NHLBI · CLEVELAND CLINIC LERNER COM-CWRU · PI VINCE, D. GEOFFREY · 2013 to 2020
$14.4M
NIH Center for Accelerated Innovations at Cleveland Clinic U54HL119810State of Michigan Economic Development Corporation Fast Forward Medical Innovation MTrac CASE-244578
6 · The paper itself

Abstract

The lack of suitable atherosclerotic calcification models and testing strategies inhibits preclinical efficacy testing of existing and novel percutaneous devices. The goal of this study is to develop a preclinical testing method for quantitatively and qualitatively evaluating the efficacy of noncompliant balloon angioplasty (NC BA) treatment in human ex vivo calcified plaque (CP). NC BA using a 3- and 4-mm diameter balloon was performed on an ex vivo tibial calcified vessel obtained from an amputation. Three-dimensional microcomputed tomography (μ-CT) imaging was performed pre- and post-BA to compare crack density in the CP. Comparing the pre- and posttreatment three-dimensional μ-CT images showed a glass-like cracking that occurred in the CP due to the BA procedure. Expansion of the 3-mm balloon showed little tissue deformation and no CP cracking. Although expansion of the 4-mm balloon occurred nonuniformly along balloon length and across the perpendicular projections, the balloon generated cracking throughout the CP, which allowed the surrounding elastic tissue to be dilated. This combined X-ray microscopy and μ-CT technique is a useful preclinical tool for quantifying the efficacy of percutaneous treatments for CP. Because of its nondestructive nature, the CP structure can be visualized pre- and posttreatment to determine the treatment effect.

Indexed as

Angioplasty, Balloon, CoronaryPlaque, AtheroscleroticHumansLower ExtremityX-Ray MicrotomographyEx vivo calcified plaque modelMicrocomputed tomographyNoncompliant balloon angioplastyPreclinical efficacy evaluation model

Identifiers

PMID33710527
OpenAlexW3135377747

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.