Evidence map›Paper›PMID 33709241›Full record

ArticleInternational journal of computer assisted radiology and surgery2021

Psychomotor skills development for Veress needle placement using a virtual reality and haptics-based simulator.

Chiara Di Vece, Cristian Luciano, Elena De Momi

Open access · hybridAbstract read
In one paragraph

Article in International journal of computer assisted radiology and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 10 papers.

0numbers the graph read from it
0cells of the map it votes in
10citing papers in PubMed
3.1field-weighted citation impact, top 8% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

10 citing papers in PubMed, 22 citations in OpenAlex.

  1. Performance using a visuo-haptic surgical simulator is affected by age.Advances in simulation (London, England) · 2026
    Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Evaluation of a Virtual Reality-Based Open Educational Resource Software.Journal of medical education and curricular development
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Chiara Di VeceDepartment of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milan, 20133, Italy.ORCID http://orcid.org/0000-0002-2853-9791
Cristian LucianoDepartment of Bioengineering and Simulation and Integrative Learning Institute, University of Illinois at Chicago, Chicago, 60607 (IL), USA.ORCID http://orcid.org/0000-0001-6521-5182
Elena De MomiDepartment of Electronics, Information and Bioengineering (DEIB), Politecnico di Milano, Milan, 20133, Italy. elena.demomi@polimi.it.ORCID http://orcid.org/0000-0002-8819-2734
Politecnico di Milano · ITUniversity of Illinois Chicago · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeVeress needle (VN) insertion, if not correctly performed, could cause severe injuries to intra-abdominal organs and vessels. Therefore, cognitive and psychomotor skills training is needed. Virtual reality (VR) and haptic technologies have the potential to offer realistic simulations.

methodsWe developed a novel VR and haptic surgical simulator for VN insertion to teach trainees how to correctly puncture the abdominal wall, experiencing realistic tactile sensations throughout the simulation. The simulator allows for both procedural and realistic training. We released two different versions: the first using the OpenHaptics[Formula: see text] (OH) Toolkit and the second exploiting CHAI3D. We evaluated the learning effect using different performance indexes (time to perform the procedure, error in insertion angle, number of undesired contacts with organs) in an insertion task for both experienced urologists and students.

resultsA general improvement of the chosen performance indexes was registered in the second repetition of the task for both groups. From the questionnaires, the simulator leveraging OH provides the trainee with a more precise haptic feedback, whereas the one exploiting CHAI3D allows them to perform the procedure more easily thanks to the better visualization of the virtual environment. The results proved that the participants appreciated both implementations, and the System Usability Scale (SUS) test resulted in a "good" usability.

conclusionThe haptics-based and VR simulator has shown the potential to be an important resource for the basic urological training in obtaining the pneumoperitoneum and improving the acquisition of the necessary psychomotor skills, allowing for extended and more effective training without compromising patient safety.

Indexed as

NeedlesUser-Computer InterfaceVirtual RealityAdultClinical CompetenceCognitionComputer SimulationFeedbackFemaleHumansImaging, Three-DimensionalMalePilot ProjectsPsychomotor PerformancePuncturesReproducibility of ResultsHapticsPsychomotor skillsSurgical simulationTrainingVeress needleVirtual reality

Identifiers

PMID33709241
PMCPMC8052214
OpenAlexW3134123410

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.