Evidence map›Paper›PMID 33709086›Full record

ArticleAdvanced photonics research2020

Sub-10-nm distance measurements between fluorophores using photon-accumulation enhanced reconstruction (PACER).

Biqin Dong, Ki-Hee Song, Janel L Davis, Hao F Zhang, Cheng Sun

Abstract read
In one paragraph

Article in Advanced photonics research, 2020. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed.

  1. Article
  2. Article
  3. Spectral precision improvement with demagnifying spectral images in spectroscopic nanoscopy.Journal of the Optical Society of America. A, Optics, image science, and vision · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors.

Biqin DongBiomedical Engineering Department, Northwestern University, Evanston, IL, 60208, USA.
Ki-Hee SongBiomedical Engineering Department, Northwestern University, Evanston, IL, 60208, USA.
Janel L DavisBiomedical Engineering Department, Northwestern University, Evanston, IL, 60208, USA.
Hao F ZhangBiomedical Engineering Department, Northwestern University, Evanston, IL, 60208, USA.
Cheng SunMechanical Engineering Department, Northwestern University, Evanston, IL, 60208, USA.

Funding

Novel Antiangiogenic Peptides for Treatment of Exudative AMDR24EY022883 · NEI · UNIVERSITY OF WISCONSIN-MADISON · PI SHEIBANI, NADER · 2013 to 2017
$6.2M
Multimodal Retinal Functional Imaging for Diabetic RetinopathyR01EY019951 · NEI · UNIVERSITY OF SOUTHERN CALIFORNIA · PI FAWZI, AMANI A, JIAO, SHULIANG · 2011 to 2015
$3.0M
Nanoscale/Molecular analysis of Fecal Colonocytes for Colorectal Cancer ScreeningR01CA165309 · NCI · NORTHWESTERN UNIVERSITY · PI BACKMAN, VADIM, ROY, HEMANT K. · 2012 to 2016
$2.8M
Investigating nanoscale neuronal damages in early glaucoma towards clinical optical detectionR01EY029121 · NEI · NORTHWESTERN UNIVERSITY · PI LIU, XIAORONG, ZHANG, HAO F · 2018 to 2021
$2.0M
Intrinsic-contrast super-resolution imaging of DNA at 2-nm resolutionR01GM139151 · NIGMS · NORTHWESTERN UNIVERSITY · PI ZHANG, HAO F · 2020 to 2023
$1.3M
NCI NIH HHS R01 CA165309NEI NIH HHS R01 EY019951NEI NIH HHS R01 EY029121NEI NIH HHS R24 EY022883NIGMS NIH HHS R01 GM139151
6 · The paper itself

Abstract

Single-molecule localization microscopy (SMLM) precisely localizes individual fluorescent molecules within the wide field of view. However, the localization precision is fundamentally limited to around 20 nm due to the physical photon limit of individual stochastic single-molecule emissions. Using spectroscopic SMLM (sSMLM) to resolve their distinct fluorescence emission spectra, we can specifically distinguish and identify individual fluorophore, even the ones of the same type. Consequently, the reported photon-accumulation enhanced reconstruction (PACER) method accumulates photons over repeated stochastic emissions from the same fluorophore to significantly improve the localization precision. This work showed the feasibility of PACER by resolving quantum dots that were 6.1 nm apart with 1.7-nm localization precision. Next, a Monte Carlo simulation is used to investigate the success probability of PACER's classification process for distance measurements under different conditions. Finally, PACER is used to resolve and measure the lengths of DNA origami nanorulers with inter-molecular spacing as small as 6 nm. Notably, the demonstrated sub-2-nm localization precision bridges the detection range between Förster Resonance Energy Transfer (FRET) and conventional SMLM. Fully exploiting the underlying imaging capability can potentially enable high-throughput inter-molecular distance measurements over a large field of view.

Indexed as

inter-molecular distance measurementssingle-molecule localization microscopyspectroscopy

Identifiers

PMID33709086
PMCPMC7942786

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.