Evidence map›Paper›PMID 33706858›Full record

ArticleComparative medicine2021

A 3D-printed Apparatus for Imaging Multiple Rats Simultaneously.

Nicholas J Harrison, Kate L Shumway, Sarah A Hansen, Charles A Maitz, Lori A Thombs, Brian K Flesner

Abstract read
In one paragraph

Article in Comparative medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Nicholas J HarrisonVeterinary Pathobiology, College of Veterinary Medicine, University of Missouri, Columbia, Missouri.
Kate L ShumwayVeterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, Missouri.
Sarah A HansenOffice of Animal Resources, University of Missouri, Columbia, Missouri.
Charles A MaitzVeterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, Missouri.
Lori A ThombsDepartment of Statistics, College of Arts and Science, University of Missouri, Columbia, Missouri.
Brian K FlesnerVeterinary Medicine and Surgery, College of Veterinary Medicine, University of Missouri, Columbia, Missouri;, Email: flesnerb@missouri.edu.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

CT (computerized tomography) is a necessary imaging modality for cancer staging and disease monitoring. Rodent models of cancer are commonly studied prior to human clinical trials, but CT in rodents can be difficult due to their small size and constant movement, which necessitates general anesthesia. Because microCT equipment is not always available, clinical CT may be a viable alternative. Limitations of microCT and clinical CT include biosecurity, anesthesia to limit image distortion due to motion, and cost. To address several of these constraints, we created a 3D-printed apparatus that accommodated simultaneous imaging of as many as 9 rats under gas anesthesia. Rats were anesthetized in series and placed in a 3 × 3 arrangement. To assess differences in attenuation between individual chambers and rows or columns in the device, we first imaged a standardized phantom plug as a control. We hypothesized that attenuation of specific rat organs would not be affected regardless of the location or position in the 3D-printed device. Four organs-liver, kidney, femur, and brain-were evaluated in 9 rats. For both the phantom and kidneys, statistically significant, but clinically negligible, effects on attenuation were noted between rows but not between columns. We attribute this finding to the absence of a top layer of the apparatus, which thus created asymmetric attenuation and beam hardening through the device. This apparatus allowed us to successfully image 9 rats simultaneously in a clinical CT machine, with negligible effects on attenuation. Planned improvements in this apparatus include completely enclosed versions for biosecure imaging.

Indexed as

Printing, Three-DimensionalAnimalsPhantoms, ImagingRatsX-Ray Microtomography

Identifiers

PMID33706858
PMCPMC8063198

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.