Retrospective Camera-Based Respiratory Gating in Clinical Whole-Heart 4D Flow MRI.

Lukas M Gottwald, Carmen P S Blanken, João Tourais, Jouke Smink, R Nils Planken, S Matthijs Boekholdt, Lilian J Meijboom, Bram F Coolen, Gustav J Strijkers, Aart J Nederveen and 1 more

Open access · hybridAbstract read
In one paragraph

Article in Journal of magnetic resonance imaging : JMRI, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
1.2field-weighted citation impact, top 21% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed, 16 citations in OpenAlex.

  1. Review
  2. Motion Mitigation Techniques for Abdominal and Cardiac MR Imaging.Journal of magnetic resonance imaging : JMRI · 2026
    Review
  3. Article
  4. Article
  5. Article
  6. Third trimester fetal 4D flow MRI with motion correction.Magnetic resonance in medicine · 2025
    Article
  7. Article
  8. 4D Flow cardiovascular magnetic resonance consensus statement: 2023 update.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Review
  9. Article
  10. Review
  11. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 2 institutions in 1 country.

Lukas M GottwaldRadiology and Nuclear Medicine, Amsterdam, Amsterdam University Medical Centers, location AMC, The Netherlands.ORCID 0000-0002-7394-821X
Carmen P S BlankenRadiology and Nuclear Medicine, Amsterdam, Amsterdam University Medical Centers, location AMC, The Netherlands.ORCID 0000-0002-3008-3236
João TouraisMR R&D-Clinical Science, Philips Healthcare, Best, The Netherlands.ORCID 0000-0002-1388-4023
Jouke SminkMR R&D-Clinical Science, Philips Healthcare, Best, The Netherlands.
R Nils PlankenCardiology, Amsterdam University Medical Centers, Amsterdam, The Netherlands.ORCID 0000-0003-3940-4670
S Matthijs BoekholdtCardiology, Amsterdam University Medical Centers, Amsterdam, The Netherlands.ORCID 0000-0002-0861-0765
Lilian J MeijboomRadiology and Nuclear Medicine, Amsterdam, Amsterdam University Medical Centers, location AMC, The Netherlands.ORCID 0000-0002-7528-8307
Bram F CoolenBiomedical Engineering and Physics, Amsterdam University Medical Centers, Amsterdam, The Netherlands.ORCID 0000-0003-3946-653X
Gustav J StrijkersBiomedical Engineering and Physics, Amsterdam University Medical Centers, Amsterdam, The Netherlands.ORCID 0000-0001-6700-5058
Aart J NederveenRadiology and Nuclear Medicine, Amsterdam, Amsterdam University Medical Centers, location AMC, The Netherlands.ORCID 0000-0002-5477-973X
Pim van OoijRadiology and Nuclear Medicine, Amsterdam, Amsterdam University Medical Centers, location AMC, The Netherlands.ORCID 0000-0001-8755-0192
Amsterdam University Medical Centers · NLPhilips (Netherlands) · NL

Funding

Stichting voor de Technische Wetenschappen 13928
6 · The paper itself

Abstract

backgroundRespiratory gating is generally recommended in 4D flow MRI of the heart to avoid blurring and motion artifacts. Recently, a novel automated contact-less camera-based respiratory motion sensor has been introduced. PURPOSE: To compare camera-based respiratory gating (CAM) with liver-lung-navigator-based gating (NAV) and no gating (NO) for whole-heart 4D flow MRI. STUDY TYPE: Retrospective. SUBJECTS: Thirty two patients with a spectrum of cardiovascular diseases. FIELD STRENGTH/SEQUENCE: A 3T, 3D-cine spoiled-gradient-echo-T1-weighted-sequence with flow-encoding in three spatial directions. ASSESSMENT: Respiratory phases were derived and compared against each other by cross-correlation. Three radiologists/cardiologist scored images reconstructed with camera-based, navigator-based, and no respiratory gating with a 4-point Likert scale (qualitative analysis). Quantitative image quality analysis, in form of signal-to-noise ratio (SNR) and liver-lung-edge (LLE) for sharpness and quantitative flow analysis of the valves were performed semi-automatically. STATISTICAL TESTS: One-way repeated measured analysis of variance (ANOVA) with Wilks's lambda testing and follow-up pairwise comparisons. Significance level of P ≤ 0.05. Krippendorff's-alpha-test for inter-rater reliability.

resultsThe respiratory signal analysis revealed that CAM and NAV phases were highly correlated (C = 0.93 ± 0.09, P < 0.01). Image scoring showed poor inter-rater reliability and no significant differences were observed (P ≥ 0.16). The image quality comparison showed that NAV and CAM were superior to NO with higher SNR (P = 0.02) and smaller LLE (P < 0.01). The quantitative flow analysis showed significant differences between the three respiratory-gated reconstructions in the tricuspid and pulmonary valves (P ≤ 0.05), but not in the mitral and aortic valves (P > 0.05). Pairwise comparisons showed that reconstructions without respiratory gating were different in flow measurements to either CAM or NAV or both, but no differences were found between CAM and NAV reconstructions. DATA

conclusionCamera-based respiratory gating performed as well as conventional liver-lung-navigator-based respiratory gating. Quantitative image quality analysis showed that both techniques were equivalent and superior to no-gating-reconstructions. Quantitative flow analysis revealed local flow differences (tricuspid/pulmonary valves) in images of no-gating-reconstructions, but no differences were found between images reconstructed with camera-based and navigator-based respiratory gating. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY: Stage 2.

Indexed as

Magnetic Resonance ImagingRespiratory-Gated Imaging TechniquesArtifactsHumansImaging, Three-DimensionalReproducibility of ResultsRetrospective StudiesSignal-To-Noise Ratio4D flow MRICameranavigatorrespiratory gating

Identifiers

PMID33694310
PMCPMC8359364
OpenAlexW3135104977

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.