Evidence map›Paper›PMID 33692329›Full record

ArticleMedical science monitor : international medical journal of experimental and clinical research2021

Long-Term Stability of Intraocular Lens with Trimmed or Untrimmed Haptics in Yamane Sutureless Intrascleral Fixation Technique.

Hui Lin, Xiancheng Ye, Xinyu Huang, Houshuo Li, Zhen Wang, Yunli Niu, Yanlong Bi

Open access · hybridAbstract read
In one paragraph

Article in Medical science monitor : international medical journal of experimental and clinical research, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
2.4field-weighted citation impact, top 12% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 21 citations in OpenAlex.

  1. Article
  2. Article
  3. Real-world outcomes of scleral-fixated intraocular lens: a multi-surgeon study comparing four-point fixation and flanged intrascleral haptic fixation techniques.Graefe's archive for clinical and experimental ophthalmology = Albrecht von Graefes Archiv fur klinische und experimentelle Ophthalmologie · 2026
    Article
  4. Article
  5. Review
  6. Review
  7. Article
  8. Self-rescue technique and Yamane's techniqueIndian journal of ophthalmology · 2023
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 2 institutions in 1 country.

Hui LinDepartment of Ophthalmology, Tongji Hospital Affiliated with Tongji University School of Medicine, Shanghai, China (mainland).
Xiancheng YeDepartment of Pharmacy, Tongji Hospital Affiliated with Tongji University School of Medicine, Shanghai, China (mainland).
Xinyu HuangDepartment of Ophthalmology, Tongji Hospital Affiliated with Tongji University School of Medicine, Shanghai, China (mainland).
Houshuo LiDepartment of Ophthalmology, Tongji Hospital Affiliated with Tongji University School of Medicine, Shanghai, China (mainland).
Zhen WangDepartment of Ophthalmology, Tongji Hospital Affiliated with Tongji University School of Medicine, Shanghai, China (mainland).
Yunli NiuDepartment of Ophthalmology, Tongji Hospital Affiliated with Tongji University School of Medicine, Shanghai, China (mainland).
Yanlong BiDepartment of Ophthalmology, Tongji Hospital Affiliated with Tongji University School of Medicine, Shanghai, China (mainland).
Tongji University · CNTongji Hospital · CN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

BACKGROUND In intraocular lens (IOL) sutureless intrascleral fixation using the Yamane technique, untrimmed haptics may be overlong in some cases due to varied haptic lengths and individual differences. However, whether trimming the haptic affects IOL stability remains unknown. MATERIAL AND METHODS Thirty-nine eyes of 39 patients who underwent Yamane sutureless intrascleral fixation surgery between October 2017 and February 2018 were analyzed retrospectively. Nineteen patients underwent surgery with untrimmed haptics and 20 patients with trimmed haptics. The slit-lamp examination, best-corrected visual acuity (BCVA), corneal endothelial cell density (ECD), IOL position, and complications were assessed. RESULTS The mean follow-up periods in the untrimmed and trimmed groups were 27.84±2.89 months and 27.85±2.41 months, respectively. The BCVA improved and ECD decreased in both groups postoperatively (all P<0.01). No significant differences were seen between the 2 groups in postoperative BCVA, postoperative ECD, IOL tilt at 3 months and 24 months, and IOL decentration at 3 months (all P>0.05). There were significant differences between the 2 groups in IOL decentration at 24 months (P<0.05). Compared with postoperative 3 months, both the postoperative IOL tilt and decentration at 24 months increased in the 2 groups (all P<0.01). Postoperative complications included IOL elevation (11% in the untrimmed group and 10% in the trimmed group), as well as haptic extrusion (16% in the untrimmed group). CONCLUSIONS The position of the IOL may change with time, but trimming the haptic to an optimum length tends to provide greater IOL stability.

Indexed as

AgedChinaFemaleHumansLenses, IntraocularLens Implantation, IntraocularMaleMiddle AgedPostoperative ComplicationsRetrospective StudiesSutureless Surgical ProceduresSuture TechniquesVisual Acuity

Identifiers

PMID33692329
PMCPMC7962415
OpenAlexW3129769927

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.