Evidence map›Paper›PMID 33691739›Full record

ArticleJournal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance2021

Fully-automated global and segmental strain analysis of DENSE cardiovascular magnetic resonance using deep learning for segmentation and phase unwrapping.

Sona Ghadimi, Daniel A Auger, Xue Feng, Changyu Sun, Craig H Meyer, Kenneth C Bilchick, Jie Jane Cao, Andrew D Scott, John N Oshinski, Daniel B Ennis and 1 more

Open access · goldAbstract readMulticenter Study
In one paragraph

Article in Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 23 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
23citing papers in PubMed, 1 pooled it
4.2field-weighted citation impact, top 5% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

23 citing papers in PubMed, 1 synthesis or guideline pooled it, 36 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Lagrangian deformation tracking for strain imaging.Progress in biomedical engineering (Bristol, England) · 2026
    Review
  5. Article
  6. Review
  7. Towards a cardiovascular magnetic resonance foundation model for multi-task cardiac image analysis.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2025
    Article
  8. Review
  9. Review
  10. Article
  11. Article
  12. Article
  13. Article
  14. Article
  15. Automated segmentation of long and short axis DENSE cardiovascular magnetic resonance for myocardial strain analysis using spatio-temporal convolutional neural networks.Journal of cardiovascular magnetic resonance : official journal of the Society for Cardiovascular Magnetic Resonance · 2023
    Article
  16. Article
  17. Article
  18. Article
  19. Article
  20. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

11 authors at 5 institutions in 2 countries.

Sona GhadimiDepartment of Biomedical Engineering, University of Virginia, Health System, Box 800759, Charlottesville, VA, 22908, USA.
Daniel A AugerDepartment of Biomedical Engineering, University of Virginia, Health System, Box 800759, Charlottesville, VA, 22908, USA.
Xue FengDepartment of Biomedical Engineering, University of Virginia, Health System, Box 800759, Charlottesville, VA, 22908, USA.
Changyu SunDepartment of Biomedical Engineering, University of Virginia, Health System, Box 800759, Charlottesville, VA, 22908, USA.
Craig H MeyerDepartment of Biomedical Engineering, University of Virginia, Health System, Box 800759, Charlottesville, VA, 22908, USA.
Kenneth C BilchickDepartment of Medicine, University of Virginia Health System, Charlottesville, VA, USA.
Jie Jane CaoDepartment of Cardiology, St. Francis Hospital, New York, NY, USA.
Andrew D ScottCardiovascular Magnetic Resonance Unit, The Royal Brompton Hospital, London, United Kingdom.
John N OshinskiDepartment of Radiology and Imaging Sciences, Emory University School of Medicine, Atlanta, GA, USA.
Daniel B EnnisDepartment of Radiology, Stanford University, Stanford, CA, USA.
Frederick H EpsteinDepartment of Biomedical Engineering, University of Virginia, Health System, Box 800759, Charlottesville, VA, 22908, USA. fhe6b@virginia.edu.ORCID 0000-0002-1954-1988
University of Virginia Health System · USEmory University · USRoyal Brompton Hospital · GBStanford University · USSt. Francis Hospital · US

Funding

Free-breathing and simultaneous multislice cine DENSE myocardial strain imagingR01HL147104 · NHLBI · UNIVERSITY OF VIRGINIA · PI EPSTEIN, FREDERICK H · 2019 to 2022
$1.5M
British Heart Foundation RG/19/1/34160NHLBI NIH HHS R01 HL147104
6 · The paper itself

Abstract

backgroundCardiovascular magnetic resonance (CMR) cine displacement encoding with stimulated echoes (DENSE) measures heart motion by encoding myocardial displacement into the signal phase, facilitating high accuracy and reproducibility of global and segmental myocardial strain and providing benefits in clinical performance. While conventional methods for strain analysis of DENSE images are faster than those for myocardial tagging, they still require manual user assistance. The present study developed and evaluated deep learning methods for fully-automatic DENSE strain analysis.

methodsConvolutional neural networks (CNNs) were developed and trained to (a) identify the left-ventricular (LV) epicardial and endocardial borders, (b) identify the anterior right-ventricular (RV)-LV insertion point, and (c) perform phase unwrapping. Subsequent conventional automatic steps were employed to compute strain. The networks were trained using 12,415 short-axis DENSE images from 45 healthy subjects and 19 heart disease patients and were tested using 10,510 images from 25 healthy subjects and 19 patients. Each individual CNN was evaluated, and the end-to-end fully-automatic deep learning pipeline was compared to conventional user-assisted DENSE analysis using linear correlation and Bland Altman analysis of circumferential strain.

resultsLV myocardial segmentation U-Nets achieved a DICE similarity coefficient of 0.87 ± 0.04, a Hausdorff distance of 2.7 ± 1.0 pixels, and a mean surface distance of 0.41 ± 0.29 pixels in comparison with manual LV myocardial segmentation by an expert. The anterior RV-LV insertion point was detected within 1.38 ± 0.9 pixels compared to manually annotated data. The phase-unwrapping U-Net had similar or lower mean squared error vs. ground-truth data compared to the conventional path-following method for images with typical signal-to-noise ratio (SNR) or low SNR (p < 0.05), respectively. Bland-Altman analyses showed biases of 0.00 ± 0.03 and limits of agreement of - 0.04 to 0.05 or better for deep learning-based fully-automatic global and segmental end-systolic circumferential strain vs. conventional user-assisted methods.

conclusionsDeep learning enables fully-automatic global and segmental circumferential strain analysis of DENSE CMR providing excellent agreement with conventional user-assisted methods. Deep learning-based automatic strain analysis may facilitate greater clinical use of DENSE for the quantification of global and segmental strain in patients with cardiac disease.

Indexed as

Deep LearningImage Interpretation, Computer-AssistedMagnetic Resonance Imaging, CineVentricular Function, LeftVentricular Function, RightAutomationCase-Control StudiesHeart DiseasesHumansLondonPredictive Value of TestsUnited StatesCardiac MRIDeep learningDENSEGlobal strainHeartMachine learningPhase unwrappingSegmental strainStrain analysis

Identifiers

PMID33691739
PMCPMC7949250
OpenAlexW3134070752

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.