SynthesisThe Cochrane database of systematic reviews2021
Internal fixation implants for intracapsular hip fractures in older adults.
Synthesis in The Cochrane database of systematic reviews, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 14 papers, 6 of them syntheses that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
14 citing papers in PubMed, 6 syntheses or guidelines pooled it, 25 citations in OpenAlex.
- Pooled it
- Surgical approaches for inserting hemiarthroplasty of the hip in people with hip fractures.The Cochrane database of systematic reviews · 2025Pooled it
- Surgical interventions for treating intracapsular hip fractures in older adults: a network meta-analysis.The Cochrane database of systematic reviews · 2022Pooled it
- Arthroplasties for hip fracture in adults.The Cochrane database of systematic reviews · 2022Pooled it
- Surgical interventions for treating extracapsular hip fractures in older adults: a network meta-analysis.The Cochrane database of systematic reviews · 2022Pooled it
- Cephalomedullary nails versus extramedullary implants for extracapsular hip fractures in older adults.The Cochrane database of systematic reviews · 2022Pooled it
- Interlocking plate compared with conventional pin fixation for undisplaced femoral neck fractures: a randomized controlled trial with radiostereometric analysis.Bone & joint open · 2026Article
- Novel internal fixation technique for Pauwels type III neck of femur fractures using the femoral neck system in conjunction with a medial buttress plate: a case report.OTA international : the open access journal of orthopaedic trauma · 2026Article
- An Acta Orthopaedica educational article: Femoral neck fractures in adults with emphasis on surgical treatment.Acta orthopaedica · 2025Review
- Comparable results for the Femoral Neck System and three-screw fixation in femoral neck fracture treatment.OTA international : the open access journal of orthopaedic trauma · 2025Article
- Multivariate analysis of blood parameters for predicting mortality in patients with hip fractures.Experimental and therapeutic medicine · 2024Article
- Article
- Interventions for reducing red blood cell transfusion in adults undergoing hip fracture surgery: an overview of systematic reviews.The Cochrane database of systematic reviews · 2023Review
- Surgical treatment options for femoral neck fractures in the elderly.International orthopaedics · 2022Review
Corrections and comments
- Commented on by
Authors and funding
6 authors at 4 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
backgroundHip fractures are a major healthcare problem, presenting a huge challenge and burden to patients, healthcare systems and society. The increased proportion of older adults in the world population means that the absolute number of hip fractures is rising rapidly across the globe. The majority of hip fractures are treated surgically. This review evaluates evidence for types of internal fixation implants used in joint-preserving surgery for intracapsular hip fractures.
objectivesTo determine the relative effects (benefits and harms) of different implants for the internal fixation of intracapsular hip fractures in older adults. SEARCH
methodsWe searched CENTRAL, MEDLINE, Embase, Web of Science, Cochrane Database of Systematic Reviews, Epistemonikos, Proquest Dissertations and Theses, and National Technical Information Service in July 2020. We also searched clinical trials databases, conference proceedings, reference lists of retrieved articles and conducted backward-citation searches. SELECTION CRITERIA: We included randomised controlled trials (RCTs) and quasi-RCTs comparing implants used for internal fixation of fragility intracapsular proximal femoral fractures in older adults. Types of implants were smooth pins (these include pins with fold-out hooks), screws, or fixed angle plates. We excluded studies in which all or most fractures were caused by specific pathologies other than osteoporosis or were the result of a high energy trauma. DATA COLLECTION AND ANALYSIS: Two review authors independently assessed studies for inclusion. One review author extracted data and assessed risk of bias which was checked by a second review author. We collected data for seven outcomes: activities of daily living (ADL), delirium, functional status, health-related quality of life (HRQoL), mobility, mortality (reported within four months of surgery as early mortality, and at 12 months since surgery), and unplanned return to theatre for treating a complication resulting directly or indirectly from the primary procedure (such as deep infection or non-union). We assessed the certainty of the evidence for these outcomes using GRADE. MAIN
resultsWe included 38 studies (32 RCTs, six quasi-RCTs) with 8585 participants with 8590 intracapsular fractures. The mean ages of participants in the studies ranged from 60 to 84 years; 73% were women, and 38% of fractures were undisplaced. We report here the findings of the four main comparisons, which were between different categories of implants. We downgraded the certainty of the outcomes for imprecision (when data were available from insufficient numbers of participants or the confidence interval (CI) was wide), study limitations (e.g. high or unclear risks of bias), and inconsistency (when we noted substantial levels of statistical heterogeneity). Smooth pins versus fixed angle plate (four studies, 1313 participants) We found very low-certainty evidence of little or no difference between the two implant types in independent mobility with no more than one walking stick (1 study, 112 participants), early mortality (1 study, 383 participants), mortality at 12 months (2 studies, 661 participants), and unplanned return to theatre (3 studies, 736 participants). No studies reported on ADL, delirium, functional status, or HRQoL. Screws versus fixed angle plates (11 studies, 2471 participants) We found low-certainty evidence of no clinically important differences between the two implant types in functional status using WOMAC (MD -3.18, 95% CI -6.35 to -0.01; 2 studies, 498 participants; range of scores from 0 to 96, lower values indicate better function), and HRQoL using EQ-5D (MD 0.03, 95% CI 0.00 to 0.06; 2 studies, 521 participants; range -0.654 (worst), 0 (dead), 1 (best)). We also found low-certainty evidence showing little or no difference between the two implant types in mortality at 12 months (RR 1.04, 95% CI 0.83 to 1.31; 7 studies, 1690 participants), and unplanned return to theatre (RR 1.10, 95% CI 0.95 to 1.26; 11 studies, 2321 participants). We found very low-certainty evidence of little or no difference between the two implant types in independent mobility (1 study, 70 participants), and early mortality (3 studies, 467 participants). No studies reported on ADL or delirium. Screws versus smooth pins (seven studies, 1119 participants) We found low-certainty evidence of no or little difference between the two implant types in mortality at 12 months (RR 1.07, 95% CI 0.85 to 1.35; 6 studies, 1005 participants; low-certainty evidence). We found very low-certainty evidence of little or no difference between the two implant types in early mortality (3 studies, 584 participants) and unplanned return to theatre (5 studies, 862 participants). No studies reported on ADL, delirium, functional status, HRQoL, or mobility. Screws or smooth pins versus fixed angle plates (15 studies, 3784 participants) In this comparison, we combined data from the first two comparison groups. We found low-certainty evidence of no or little difference between the two groups of implants in mortality at 12 months (RR 1.04, 95% CI.083 to 1.31; 7 studies, 1690 participants) and unplanned return to theatre (RR 1.02, 95% CI 0.88 to 1.18; 14 studies, 3057 participants). We found very low-certainty evidence of little or no difference between the two groups of implants in independent mobility (2 studies, 182 participants), and early mortality (4 studies, 850 participants). We found no additional evidence to support the findings for functional status or HRQoL as reported in 'Screws versus fixed angle plates'. No studies reported ADL or delirium. AUTHORS'
conclusionsThere is low-certainty evidence that there may be little or no difference between screws and fixed angle plates in functional status, HRQoL, mortality at 12 months, or unplanned return to theatre; and between screws and pins in mortality at 12 months. The limited and very low-certainty evidence for the outcomes for which data were available for the smooth pins versus fixed angle plates comparison, as well as the other outcomes for which data were available for the screws and fixed angle plates, and screws and pins comparisons means we have very little confidence in the estimates of effect for these outcomes. Additional RCTs would increase the certainty of the evidence. We encourage such studies to report outcomes consistent with the core outcome set for hip fracture, including long-term quality of life indicators such as ADL and mobility.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.