Investigating the cause of hemolysis in patients supported by a pulsatile ventricular assist device.

Takeaki Harada, Yoshihisa Tanoue, Yasuhisa Oishi, Hiromichi Sonoda, Satoshi Kimura, Satoshi Fujita, Tomoki Ushijima, Ryo Kosaka, Koichi Kojima, Akira Shiose

Open access · greenAbstract read
PubMed Publisher
In one paragraph

Article in Heart and vessels, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
–field-weighted citation impact, top 98% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 1 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 2 institutions in 1 country.

Takeaki HaradaDepartment of Cardiovascular Surgery, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Yoshihisa TanoueDepartment of Cardiovascular Surgery, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Yasuhisa OishiDepartment of Cardiovascular Surgery, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Hiromichi SonodaDepartment of Cardiovascular Surgery, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Satoshi KimuraDepartment of Cardiovascular Surgery, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Satoshi FujitaDepartment of Cardiovascular Surgery, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Tomoki UshijimaDepartment of Cardiovascular Surgery, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan.
Ryo KosakaHealth Research Institute, National Institute of Advanced Industrial Science and Technology (AIST), Tsukuba, Japan.
Koichi KojimaResearch & Development Department, IWAKI Co., Ltd., Saitama, Japan.
Akira ShioseDepartment of Cardiovascular Surgery, Kyushu University Hospital, 3-1-1 Maidashi, Higashi-ku, Fukuoka, 812-8582, Japan. shiose@heart.med.kyushu-u.ac.jp.ORCID http://orcid.org/0000-0002-0865-0169
Kyushu University Hospital · JPNational Institute of Advanced Industrial Science and Technology · JP

Funding

Japan Society for the Promotion of Science JP20K17719
6 · The paper itself

Abstract

A survey conducted by Abiomed, Inc. revealed that 10 of 60 patients who received ventricular assistance via the AB5000 ventricular assist device (VAD) experienced hemolysis. The present study was conducted to investigate which factors influence hemolysis under pulsatile-flow VADs such as the AB5000. We compared the specificity of the AB5000 and its driving console with those of the NIPRO-VAD and VCT50χ under severe heart failure conditions using a mock circulatory system with a glycerol water solution. We used the mock circuit with bovine blood to confirm which pump conditions were most likely to cause hemolysis. In addition, we measured the shear velocity using particle image velocimetry by analyzing the seeding particle motion for both the AB5000 and NIPRO-VAD under the same conditions as those indicated in the initial experiment. Finally, we analyzed the correlation between negative pressure, exposure time, and hemolysis by continuously exposing fixed vacuum pressures for fixed times in a sealed device injected with bovine blood. Applying higher vacuum pressure to the AB5000 pump yielded a larger minimum inlet pressure and a longer exposure time when the negative pressure was under - 10 mmHg. The plasma-free hemoglobin increased as more negative pressure was driven into the AB5000 pump. Moreover, the negative pressure interacted with the exposure time, inducing hemolysis. This study revealed that negative pressure and exposure time were both associated with hemolysis.

Indexed as

Anemia, HemolyticFollow-Up StudiesHeart-Assist DevicesHeart FailureHematologic TestsHemolysisHumansRetrospective StudiesExposure timeHemolysisNegative pressurePulsatile flowVentricular assist device

Identifiers

PMID33686554
OpenAlexW3133664441

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.