Evidence map›Paper›PMID 33683464›Full record

ArticleEJNMMI physics2021

Improved PET/MRI accuracy by use of static transmission source in empirically derived hardware attenuation correction.

Adam Farag, R Terry Thompson, Jonathan D Thiessen, Frank S Prato, Jean Théberge

Open access · goldAbstract read
In one paragraph

Article in EJNMMI physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.

0numbers the graph read from it
0cells of the map it votes in
1citing papers in PubMed
0.4field-weighted citation impact, top 39% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

1 citing paper in PubMed, 3 citations in OpenAlex.

  1. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Adam FaragLawson Health Research Institute, Imaging Division, London, Ontario, Canada. adam.farag@uwo.ca.ORCID http://orcid.org/0000-0002-8439-9498
R Terry ThompsonLawson Health Research Institute, Imaging Division, London, Ontario, Canada.
Jonathan D ThiessenLawson Health Research Institute, Imaging Division, London, Ontario, Canada.
Frank S PratoLawson Health Research Institute, Imaging Division, London, Ontario, Canada.
Jean ThébergeLawson Health Research Institute, Imaging Division, London, Ontario, Canada.
Western University · CA

Funding

Canadian Network for Research and Innovation in Machining Technology, Natural Sciences and Engineering Research Council of Canada RGPIN-2016-05055
6 · The paper itself

Abstract

backgroundAccurate quantification of radioactivity, measured by an integrated positron emission tomography (PET) and magnetic resonance imaging (MRI) system, is still a challenge. One aspect of such a challenge is to correct for the hardware attenuation, such as the patient table and radio frequency (RF) resonators. For PET/MRI systems, computed tomography (CT) is commonly used to produce hardware attenuation correction (AC) maps, by converting Hounsfield units (HU) to a linear attenuation coefficients (LAC) map at the PET energy level 511 keV, using a bilinear model. The model does not address beam hardening, nor higher density materials, which can lead to inaccurate corrections. PURPOSE: In this study, we introduce a transmission-based (TX-based) AC technique with a static Germanium-68 (Ge-68) transmission source to generate hardware AC maps using the PET/MRI system itself, without the need for PET or medical CT scanners. The AC TX-based maps were generated for a homogeneous cylinder, made of acrylic as a validator. The technique thereafter was applied to the patient table and posterior part of an RF-phased array used in cardiovascular PET/MRI imaging. The proposed TX-based, and the CT-based, hardware maps were used in reconstructing PET images of one cardiac patient, and the results were analysed and compared.

resultsThe LAC derived by the TX-based method for the acrylic cylinder is estimated to be 0.10851 ± 0.00380 cm

conclusionsThe LAC of the acrylic cylinder measurements using the TX-based technique was in agreement with those in the literature confirming the validity of the technique. The over-estimation of photon counts caused by the CT-based model used for the patient table was improved by the TX-based technique. Therefore, TX-based AC of hardware using the PET/MRI system itself is possible and can produce more accurate images when compared to the CT-based hardware AC in cardiac PET images.

Indexed as

Cardiac imagingHardware attenuation mapPET/MRITransmission-based attenuation correction

Identifiers

PMID33683464
PMCPMC7940463
OpenAlexW3135005809

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.