Evidence map›Paper›PMID 33683309›Full record

ArticleRadiation protection dosimetry2021

QUANTIFICATION OF PULMONARY PATHOLOGY IN CYSTIC FIBROSIS-COMPARISON BETWEEN DIGITAL CHEST TOMOSYNTHESIS AND COMPUTED TOMOGRAPHY.

C Meltzer, M Gilljam, J Vikgren, R R Norrlund, K Vult von Steyern, M Båth, Å A Johnsson

Open access · hybridAbstract read
In one paragraph

Article in Radiation protection dosimetry, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
0.3field-weighted citation impact, top 43% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 3 citations in OpenAlex.

  1. Article
  2. Next-generation digital chest tomosynthesis.Journal of clinical imaging science · 2024
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

C MeltzerDepartment of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Bruna stråket 11b V 2 SU/Sahlgrenska, 413 45 Gothenburg, Sweden.ORCID 0000-0003-0752-028X
M GilljamGothenburg CF-Center, Sahlgrenska University Hospital, Gothenburg, Sweden.
J VikgrenDepartment of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Bruna stråket 11b V 2 SU/Sahlgrenska, 413 45 Gothenburg, Sweden.
R R NorrlundDepartment of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Bruna stråket 11b V 2 SU/Sahlgrenska, 413 45 Gothenburg, Sweden.
K Vult von SteyernCenter for Medical Imaging and Physiology, Skåne University Hospital, Getingevägen 4, 22185 Lund, Sweden.
M BåthDepartment of Medical Physics and Biomedical Engineering, Sahlgrenska University Hospital, Gula stråket 2B, Plan 3, 413 45 Gothenburg, Sweden.
Å A JohnssonDepartment of Radiology, Institute of Clinical Sciences, Sahlgrenska Academy, University of Gothenburg, Bruna stråket 11b V 2 SU/Sahlgrenska, 413 45 Gothenburg, Sweden.
Sahlgrenska University Hospital · SEGetinge (Sweden) · SEOslo University Hospital · NO

Funding

ALF-agreement ALFGBG-718111Department of Radiology, Oslo University HospitalSwedish Research Council 2013/3477
6 · The paper itself

Abstract

purposeDigital tomosynthesis (DTS) is currently undergoing validation for potential clinical implications. The aim of this study was to investigate the potential for DTS as a low-dose alternative to computed tomography (CT) in imaging of pulmonary pathology in patients with cystic fibrosis (CF).

methodsDTS and CT were performed as part of the routine triannual follow-up in 31 CF patients. Extent of disease was quantified according to modality-specific scoring systems. Statistical analysis included Spearman's rank correlation coefficient (r) and Krippendorff's alpha (α). MAJOR

findingsThe median effective dose was 0.14 for DTS and 2.68 for CT. Intermodality correlation was very strong for total score and the subscores regarding bronchiectasis and bronchial wall-thickening (r = 0.82-0.91, P < 0.01). Interobserver reliability was high for total score, bronchiectasis and mucus plugging (α = 0.83-0.93) in DTS.

conclusionChest tomosynthesis could be a low-dose alternative to CT in quantitative estimation of structural lung disease in CF.

Indexed as

Cystic FibrosisHumansLungRadiographyReproducibility of ResultsTomography, X-Ray Computed

Identifiers

PMID33683309
PMCPMC8507459
OpenAlexW3133543222

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.