Evidence map›Paper›PMID 33682783›Full record

ArticleTechnology and health care : official journal of the European Society for Engineering and Medicine2021

Preliminary study on the new wound monitoring technology using co-planar waveguide sensor: Modeling and simulation.

Liang Zhang, Zhenyu Ji

Abstract read
In one paragraph

Article in Technology and health care : official journal of the European Society for Engineering and Medicine, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

2 authors.

Liang ZhangSchool of Basic Medical Science, Air Force Military Medical University, Xi'an, Shaanxi, China.
Zhenyu JiFaculty of Military Biomedical Engineering, Air Force Military Medical University, Xi'an, Shaanxi, China.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundWound monitoring is very meaningful for the clinical research, diagnosis and treatment. But the existing wound monitoring technology is hard to meet the needs of modern medical care in terms of real-time, non-invasive and anti-interference.

objectiveTo solve this problem, this paper proposed a new kind of monitoring technology based on the co-planar waveguide transmission line theory and assessed the application value of this method as a wound monitoring technology.

methodsThe simplified wound model included the skin, fat, muscle, tissue fluid and bandage and a new co-planar waveguide sensor were designed and established. All of the simulation was achieved in the electromagnetic special software. The data processing method was based on the transmission line theory.

resultsDetailed analyses of the results from the simulation were conducted. The sensor has a good monitoring effect in the low frequency band. The monitoring results could be influenced by the thickness of the bandage outside the wound. The thickness of the bandage should not be larger than 10 mm. The effective monitoring area of the sensor is 30 × 20 mm2.

conclusionsThe proposed sensor based on the CPW transmission principle in this paper has good wound monitoring potential.

Indexed as

BandagesSkinComputer SimulationElectromagnetic PhenomenaHumansTechnologyCPWelectromagnetic fieldimpedancemonitoring technologywound healing

Identifiers