Evidence map›Paper›PMID 33681855›Full record

ArticleJSES international2021

Ulnar collateral ligament dysfunction increases stress on the humeral capitellum: a finite element analysis.

Keita Kamei, Eiji Sasaki, Kazuhiro Fujisaki, Yoshifumi Harada, Yuji Yamamoto, Yasuyuki Ishibashi

Abstract read
In one paragraph

Article in JSES international, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed.

  1. Article
  2. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Keita KameiDepartment of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan.
Eiji SasakiDepartment of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan.
Kazuhiro FujisakiDepartment of Intelligent Machines and System Engineering, Faculty of Science and Technology, Hirosaki University, Hirosaki, Japan.
Yoshifumi HaradaDepartment of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan.
Yuji YamamotoDepartment of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan.
Yasuyuki IshibashiDepartment of Orthopaedic Surgery, Hirosaki University Graduate School of Medicine, Hirosaki, Japan.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundRepetitive mechanical stress on the elbow joint during throwing is a cause of ulnar collateral ligament dysfunction that may increase the compressive force on the humeral capitellum. This study aimed to examine the effects of ulnar collateral ligament material properties on the humeral capitellum under valgus stress using the finite element method.

methodsComputed tomography data of the dominant elbow of five healthy adults were used to create finite element models. The elbows were kept at 90° of flexion with the forearm in the neutral position, and the ulnar collateral ligament was reproduced using truss elements. The proximal humeral shaft was restrained, and valgus torque of 40 N·m was applied to the forearm. The ulnar collateral ligament condition was changed to simulate ulnar collateral ligament dysfunction. Ulnar collateral ligament stiffness values were changed to 72.3 N/mm, 63.3 N/mm, 54.2 N/mm, 45.2 N/mm, and 36.1 N/mm to simulate ulnar collateral ligament laxity. The ulnar collateral ligament toe region width was changed in increments of 0.5 mm from 0.0 to 2.5 mm to simulate ulnar collateral ligament loosening. We assessed the maximum equivalent stress and stress distribution on the humeral capitellum under these conditions.

resultsAs ulnar collateral ligament stiffness decreased, the maximum equivalent stress on the humeral capitellum gradually increased under elbow valgus stress (

conclusionUnder elbow valgus stress with elbow flexion of 90° and the forearm in the neutral position, ulnar collateral ligament dysfunction increased equivalent stress on the humeral capitellum during the finite element analysis. The highest equivalent stress was noted on the lateral part of the capitellum.

Indexed as

elbowfinite element methodhumeral capitellummaterial properties of ulnar collateral ligamentosteochondritis dissecansUlnar collateral ligament

Identifiers

PMID33681855
PMCPMC7910738

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.