Evidence map›Paper›PMID 33673882›Full record

ArticleJournal of the American Association for Laboratory Animal Science : JAALAS2021

Assessing Accumulation of Organic Material on Rodent Cage Accessories.

Kenneth P Allen, Tarrant J Csida, Joseph D Thulin

Abstract read
In one paragraph

Article in Journal of the American Association for Laboratory Animal Science : JAALAS, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 5 papers.

0numbers the graph read from it
0cells of the map it votes in
5citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

5 citing papers in PubMed.

  1. Performance Validated 8-Week Sanitation Interval for Mouse (Mus musculus) Wire-Bar Lids: ATP and CFU Outcomes.Journal of the American Association for Laboratory Animal Science : JAALAS · 2026
    Article
  2. Analysis of IVC Microenvironments During an Extended Cage-Change Interval in Rats (Rattus norvegicus).Journal of the American Association for Laboratory Animal Science : JAALAS · 2026
    Article
  3. Enhancing Rodent Welfare, Cost Savings, and Efficiency: Implementation and Review of Data-Driven Improvements.Journal of the American Association for Laboratory Animal Science : JAALAS · 2026
    Review
  4. Evaluation and Refinement of a Spot-change-only Cage Management System for Mice.Journal of the American Association for Laboratory Animal Science : JAALAS · 2022
    Article
  5. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors.

Kenneth P AllenBiomedical Resource Center, Office of Research, Milwaukee, Wisconsin; Department of Microbiology and Molecular Genetics, Milwaukee, Wisconsin;, Email: kpallen@mcw.edu.
Tarrant J CsidaBiomedical Resource Center, Office of Research, Milwaukee, Wisconsin.
Joseph D ThulinBiomedical Resource Center, Office of Research, Milwaukee, Wisconsin; Department of Physiology, Medical College of Wisconsin, Milwaukee, Wisconsin.

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

According to the 8th edition of the Guide for the Care and Use of Laboratory Animals (the Guide), rodent cage accessories, such as filter tops, should be sanitized at least once every 2 wk. We performed a study to test the hypothesis that organic contamination (measured by ATP content, expressed as relative light units (RLU)) of cage accessories (wire bar inserts and filter top lids) does not differ at 2 wk (14 d) as compared with 30, 60, and 90-d time points after cage change even when in constant use. An additional time point for filter top lids of 180 d after cage change was also evaluated. Eight groups were studied: the wire bar inserts and filter top lids used for mice and rats, in both static and individually ventilated cages (IVC). When analyzing data from both mouse and rat static and IVC caging, we found that the mean RLU values for mouse IVC and rat static and IVC cage components were below 100,000 RLU at the 14-d time point. The mean value for the mouse static group was slightly above 100,000 RLU at this time point. Based on this observation, we considered 100,000 RLU to be an appropriate actionable level. We concluded that changing wire bar inserts at least every 14 d, as recommended in the Guide for sanitizing these components in mouse and rat static cages, may be considered acceptable. This interval could be extended for mouse and rat IVC cages up to 90 d while remaining below this limit. Filter top lids for mouse static cages should be changed at least every 30 d, but static rat and IVC mouse/rat filter top lids could be changed up to every 180 d, while still staying below this actionable level of contamination.

Indexed as

Housing, AnimalRodentiaAnimalsAnimals, LaboratoryMiceRatsVentilation

Identifiers

PMID33673882
PMCPMC8145131

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.