Evidence map›Paper›PMID 33671202›Full record

ArticleSensors (Basel, Switzerland)2021

Extraction and Analysis of Respiratory Motion Using a Comprehensive Wearable Health Monitoring System.

Uduak Z George, Kee S Moon, Sung Q Lee

Open access · goldAbstract read
In one paragraph

Article in Sensors (Basel, Switzerland), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 12 papers.

0numbers the graph read from it
0cells of the map it votes in
12citing papers in PubMed
2.5field-weighted citation impact, top 10% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

12 citing papers in PubMed, 21 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Article
  12. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

3 authors at 2 institutions in 2 countries.

Uduak Z GeorgeDepartment of Mathematics and Statistics, San Diego State University, San Diego, CA 92182, USA.ORCID 0000-0003-2208-3671
Kee S MoonDepartment of Mechanical Engineering, San Diego State University, San Diego, CA 92182, USA.
Sung Q LeeElectronics and Telecommunications Research Institute, Daejeon 34129, Korea.ORCID 0000-0001-7473-5446
San Diego State University · USElectronics and Telecommunications Research Institute · KR

Funding

The Research Infrastructure Core of SDSU HealthLINK Center for Transdisciplinary Health Disparities ResearchU54MD012397 · NIMHD · SAN DIEGO STATE UNIVERSITY · PI Angelica M Riestra · 2018 to 2026
$39.0M
Urgent Competitive Revision to Existing NIH Grants and Cooperative Agreements (Urgent Supplement - Clinical Trial Optional)U24MD015970 · NIMHD · MOREHOUSE SCHOOL OF MEDICINE · PI Sandra Perreira Chang, Elizabeth O. Ofili · 2020 to 2026
$20.6M
Building Capacity and Infrastructure for Population Health and Health Disparities Research at San Diego State UniversityS21MD010690 · NIMHD · SAN DIEGO STATE UNIVERSITY · PI AYALA, GUADALUPE X, CASTILLO, JOSE E · 2016 to 2020
$10.0M
KIAT N015800182NIMHD NIH HHS S21 MD010690NIMHD NIH HHS U24 MD015970NIMHD NIH HHS U54 MD012397NIMHD NIH HHS U54MD012397
6 · The paper itself

Abstract

Respiratory activity is an important vital sign of life that can indicate health status. Diseases such as bronchitis, emphysema, pneumonia and coronavirus cause respiratory disorders that affect the respiratory systems. Typically, the diagnosis of these diseases is facilitated by pulmonary auscultation using a stethoscope. We present a new attempt to develop a lightweight, comprehensive wearable sensor system to monitor respiration using a multi-sensor approach. We employed new wearable sensor technology using a novel integration of acoustics and biopotentials to monitor various vital signs on two volunteers. In this study, a new method to monitor lung function, such as respiration rate and tidal volume, is presented using the multi-sensor approach. Using the new sensor, we obtained lung sound, electrocardiogram (ECG), and electromyogram (EMG) measurements at the external intercostal muscles (EIM) and at the diaphragm during breathing cycles with 500 mL, 625 mL, 750 mL, 875 mL, and 1000 mL tidal volume. The tidal volumes were controlled with a spirometer. The duration of each breathing cycle was 8 s and was timed using a metronome. For each of the different tidal volumes, the EMG data was plotted against time and the area under the curve (AUC) was calculated. The AUC calculated from EMG data obtained at the diaphragm and EIM represent the expansion of the diaphragm and EIM respectively. AUC obtained from EMG data collected at the diaphragm had a lower variance between samples per tidal volume compared to those monitored at the EIM. Using cubic spline interpolation, we built a model for computing tidal volume from EMG data at the diaphragm. Our findings show that the new sensor can be used to measure respiration rate and variations thereof and holds potential to estimate tidal lung volume from EMG measurements obtained from the diaphragm.

Indexed as

DiaphragmRespirationTidal VolumeWearable Electronic DevicesAcousticsElectrocardiographyHumansRespiratory Soundsbiomedical signal processingcubic spline interpolationmedical equipmentmulti-sensor fusionrespirationtidal volumewearable biomedical sensors

Identifiers

PMID33671202
PMCPMC7923104
OpenAlexW3129361539

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.