Evidence map›Paper›PMID 33664891›Full record

ArticleJournal of arrhythmia2021

Effect of fluoroscopy frame rate on radiation exposure and in-hospital outcomes in three-dimensional electroanatomic mapping guided procedures.

Muzaffar Ali, Deepak Padmanabhan, Khalil Kanjwal, Milan Kumar Ghadei, Anju Kottayan, Bharatraj Banavalikar, Jayaprakash Shenthar

Open access · goldAbstract read
In one paragraph

Article in Journal of arrhythmia, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 2 papers.

0numbers the graph read from it
0cells of the map it votes in
2citing papers in PubMed
1.3field-weighted citation impact, top 20% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

2 citing papers in PubMed, 9 citations in OpenAlex.

  1. Article
  2. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

7 authors at 3 institutions in 2 countries.

Muzaffar AliDepartment of Cardiac Electrophysiology Sri Jayadeva Institute of Cardiovascular Sciences and Research Bangalore India.ORCID https://orcid.org/0000-0002-3489-5864
Deepak PadmanabhanDepartment of Cardiac Electrophysiology Sri Jayadeva Institute of Cardiovascular Sciences and Research Bangalore India.
Khalil KanjwalDepartment of Cardiology Division of Clinical Cardiac Electrophysiology McLaren Greater Lansing Hospital Lansing MI USA.ORCID https://orcid.org/0000-0002-2640-6610
Milan Kumar GhadeiDepartment of Cardiac Electrophysiology Sri Jayadeva Institute of Cardiovascular Sciences and Research Bangalore India.
Anju KottayanDepartment of Cardiac Electrophysiology Sri Jayadeva Institute of Cardiovascular Sciences and Research Bangalore India.
Bharatraj BanavalikarDepartment of Cardiac Electrophysiology Sri Jayadeva Institute of Cardiovascular Sciences and Research Bangalore India.
Jayaprakash ShentharDepartment of Cardiac Electrophysiology Sri Jayadeva Institute of Cardiovascular Sciences and Research Bangalore India.
Sri Jayadeva Institute of Cardiovascular Sciences and Research · INMcLaren Greater Lansing · USSher-i-Kashmir Institute of Medical Sciences · IN

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundFluoroscopic imaging involves exposure of the patients and the laboratory staff to ionizing radiation. One of the strategies that reduce such exposure in an electrophysiology laboratory is using a three-dimensional electroanatomic mapping (3D EAM) system for performing these procedures. In this analysis, we have analyzed the effect of fluoroscopy frame rate on the radiation exposure and in-hospital outcomes in ablation procedures performed under 3D EAM guidance.

methodsWe retrospectively analyzed all the ablation procedures performed under 3D EAM guidance at our institute from September 2015 to December 2018. The procedures were divided into two groups based on whether the procedures were performed before (pre) or after (post) January 26, 2018. After January 2018, fluoroscopy was used at a frame rate of 3.75 frames per second (fps). Radiation exposure indices and in-hospital outcomes were compared between the two groups.

resultsAblation procedures included in the analysis were ventricular arrhythmias (n = 192), atrial flutter (115), atrial tachycardia (AT) (43), and atrial fibrillation (AF) (30). Over the study period, there was a significant reduction in procedure time, fluoroscopy time, dose area product, and effective dose (ED) (

conclusionThe use of 3D EAM combined with decreasing the fluoroscopy frame rate significantly reduced the total radiation exposure without adversely affecting in-hospital outcomes.

Indexed as

atrial fluttereffective doseradiation exposurethree‐dimensional electroanatomic mappingventricular tachycardia

Identifiers

PMID33664891
PMCPMC7896476
OpenAlexW3119013090

What OpenQuestion holds

Textmetadata
LicenceCC BY-NC-ND
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.