Evidence map›Paper›PMID 33663454›Full record

ArticleBMC oral health2021

Comparison of novel and established caries diagnostic methods: a clinical study on occlusal surfaces.

Friederike Litzenburger, Gerrit Schäfer, Reinhard Hickel, Jan Kühnisch, Katrin Heck

Open access · goldAbstract read
In one paragraph

Article in BMC oral health, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.6field-weighted citation impact, top 18% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 15 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Review
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 1 country.

Friederike LitzenburgerDepartment of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilians-University of Munich, Munich, Germany. soechtig@dent.med.uni-muenchen.de.
Gerrit SchäferDepartment of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilians-University of Munich, Munich, Germany.
Reinhard HickelDepartment of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilians-University of Munich, Munich, Germany.
Jan KühnischDepartment of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilians-University of Munich, Munich, Germany.
Katrin HeckDepartment of Conservative Dentistry and Periodontology, University Hospital, Ludwig-Maximilians-University of Munich, Munich, Germany.
Ludwig-Maximilians-Universität München · DE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe purpose of this prospective clinical diagnostic study with validation was to compare the diagnostic accuracy of near-infrared transillumination (NIRT), laser fluorescence measurement (LF), alternating current impedance spectroscopy (ACIS) and their combinations as adjunct methods to visual examination (VE) for occlusal caries detection using a hybrid reference standard.

methodsNinety-six first and second non-cavitated permanent molars from 76 individuals (mean age 24.2) were investigated using (VE) (ICDAS) and bitewing radiography (BWR), as well as NIRT, LF and ACIS. The findings of BWR and NIRT were evaluated by two examiners while the other examinations were conducted by one calibrated dentist. The hybrid reference standard consisted of non-operative validation based on the results of VE and BWR and operative validation. Statistical analysis included cross-tabulations, calculation of sensitivity, specificity and area under the receiver operating characteristic curve at three diagnostic thresholds: caries in general, enamel caries and dentin caries.

resultsNIRT, LF and ACIS exhibited high sensitivity for caries in general [1.00 (1.00-1.00), 0.77 (0.65-0.88), 0.75 (0.63-0.87)) and for dentin caries (0.97 (0.91-1.03), 0.76 (0.76-0.90), 0.64 (0.47-0.80)]. Sensitivity values for enamel caries were weak (0.21, 0.11, 0.37). Specificity values did not fall below 0.65 (NIRT) for all categories and methods, except for NIRT at the caries detection threshold (0.27). A combination of LF and ACIS with VE improved the diagnostic performance at the overall and the enamel caries threshold. The other methods showed fair to excellent discrimination at the overall caries threshold (NIRT 0.64, LF 0.89 and ACIS 0.86) and acceptable discrimination at the dentin caries threshold (NIRT 0.82, LF 0.81 and ACIS 0.79). AUROC for enamel caries exhibited the weakest discrimination. Accuracy was 65.6% for VE, 69.8% for BWR, 50.0% for NIRT, 53.1% for LF and 74.0% for ACIS. Reliability assessment for BWR and NIRT showed at least substantial agreements for all analyses.

conclusionsThe methods, NIRT, LF and ACIS, revealed different potential but no impeccable performance for occlusal caries detection. All are suitable instruments to detect hidden carious lesion in dentin. As auxiliaries to VE, LF and ACIS showed an increase in diagnostic performance.

Indexed as

Dental CariesDental Caries SusceptibilityAdultDentinFluorescenceHumansProspective StudiesRadiography, BitewingReproducibility of ResultsSensitivity and SpecificityYoung AdultAlternating current impedance spectroscopyBitewing radiographyDental cariesDiagnostic imagingLaser‐fluorescenceNear‐infrared transilluminationOcclusal cariesOcclusal caries detectionSensitivitySpecificity

Identifiers

PMID33663454
PMCPMC7934514
OpenAlexW3135444290

What OpenQuestion holds

Textmetadata
LicenceCC BY
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.