Evidence map›Paper›PMID 33661396›Full record

ArticleEuropean spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society2021

Vertebral balloon kyphoplasty versus vertebral body stenting in non-osteoporotic vertebral compression fractures at the thoracolumbar junction: a comparative radiological study and finite element analysis (BONEXP study).

Tanguy Vendeuvre, Paul Brossard, Jean-Baptiste Pic, Maxime Billot, Louis-Etienne Gayet, Pierre Pries, Simon Teyssédou, Arnaud Germaneau, Philippe Rigoard

Abstract read
PubMed Publisher
In one paragraph

Article in European spine journal : official publication of the European Spine Society, the European Spinal Deformity Society, and the European Section of the Cervical Spine Research Society, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 8 papers.

0numbers the graph read from it
0cells of the map it votes in
8citing papers in PubMed
1.9field-weighted citation impact, top 15% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

8 citing papers in PubMed, 12 citations in OpenAlex.

  1. Review
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
  7. Review
  8. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

9 authors at 2 institutions in 1 country.

Tanguy Vendeuvre *Department of Spine, Neuromodulation and Rehabilitation, Poitiers University Hospital, Poitiers, France.
Paul Brossard *Department of Spine, Neuromodulation and Rehabilitation, Poitiers University Hospital, Poitiers, France.
Jean-Baptiste PicDepartment of Spine, Neuromodulation and Rehabilitation, Poitiers University Hospital, Poitiers, France.
Maxime BillotPRISMATICS Lab, Poitiers University Hospital, Poitiers, France.
Louis-Etienne GayetDepartment of Orthopaedic Surgery and Traumatology, Poitiers University Hospital, Poitiers, France.
Pierre PriesDepartment of Spine, Neuromodulation and Rehabilitation, Poitiers University Hospital, Poitiers, France.
Simon TeyssédouDepartment of Spine, Neuromodulation and Rehabilitation, Poitiers University Hospital, Poitiers, France.
Arnaud GermaneauInstitut Pprime UPR 3346 CNRS, Université de Poitiers - ISAE-ENSMA, Bd Marie et Pierre Curie, Futuroscope, 86000, Poitiers, France. arnaud.germaneau@univ-poitiers.fr.ORCID 0000-0001-6150-4104
Philippe RigoardDepartment of Spine, Neuromodulation and Rehabilitation, Poitiers University Hospital, Poitiers, France.
Université de Poitiers · FRCentre National de la Recherche Scientifique · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

objectiveTo compare radiologically balloon kyphoplasty (BKP) and vertebral compression fracture (VCF) expansion and corroborate with a finite element (FE) analysis. The principle of BKP is to stabilize VCF by restoring vertebral body anatomy using bone expansion and cement filling. More recently, vertebral body stenting (VBS) has been developed to reduce the loss of vertebral height observed after balloon deflation.

methodsA retrospective, monocentric and continuous study of 60 non-osteoporotic fractures of the thoracolumbar junction treated by vertebral bone expansion was carried out over three years. The main endpoint was radiological correction of vertebral kyphosis (VK) at 3 months. The other studied parameters were vertebral height, index of Farcy, index of Beck, cement leakages and their location. A FE model was developed to analyze effects linked to the stent during cement injection, specifically throughout the risk of cement leakage evaluation.

resultsAfter three months, average reduction of VK was 4.73° ± 4.8° after BKP, and 4.63° ± 2.7° after VBS. There was no difference between the two techniques, but cement leakage was significantly greater with BKP (41.7%) than with VBS (4.2%). FE analysis showed substantial changes of the cement flow orientation in the presence of a stent.

conclusionBKP and VBS offer comparable expansion with no added value of VBS in non-osteoporotic VCF reduction. VBS technique appears to prevent cement leakage due to its mesh architecture hindering the leaking process. In counterpart, such balloon expansion is likely to require higher pressure to deploy the stent. This could be an important parameter to take into account in young patients with high bone density.

Indexed as

Fractures, CompressionKyphoplastySpinal FracturesFinite Element AnalysisHumansRetrospective StudiesStentsVertebral BodyBalloon kyphoplastyBone expansionMinimally invasive techniqueThoracolumbar spineVertebral body stentingVertebral compression fracture

Identifiers

PMID33661396
OpenAlexW3133725165

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.