Evidence map›Paper›PMID 33661374›Full record

ArticleEuropean journal of orthopaedic surgery & traumatology : orthopedie traumatologie2022

Systematic use of short unicortical epiphyseal locking screws versus full-length unicortical locking screws in distal radius fracture volar plating: A prospective and comparative study.

M Artuso, M Protais, O Herisson, A Miquel, A Cambon-Binder, A Sautet

Abstract read
PubMed Publisher
In one paragraph

Article in European journal of orthopaedic surgery & traumatology : orthopedie traumatologie, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 4 papers, 1 of them a synthesis that pooled it.

0numbers the graph read from it
0cells of the map it votes in
4citing papers in PubMed, 1 pooled it
1.0field-weighted citation impact, top 25% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

4 citing papers in PubMed, 1 synthesis or guideline pooled it, 8 citations in OpenAlex.

  1. Pooled it
  2. Article
  3. Article
  4. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors at 1 institution in 1 country.

M ArtusoOrthopedics and Hand Surgery Department, Saint-Antoine Hospital, 184 Rue du Faubourg Saint-Antoine, Paris, 75012, France. mickael.artuso@gmail.com.ORCID http://orcid.org/0000-0002-7836-9612
M ProtaisOrthopedics and Hand Surgery Department, Saint-Antoine Hospital, 184 Rue du Faubourg Saint-Antoine, Paris, 75012, France.
O HerissonOrthopedics and Hand Surgery Department, Saint-Antoine Hospital, 184 Rue du Faubourg Saint-Antoine, Paris, 75012, France.
A MiquelRadiology Department, Saint-Antoine Hospital, 184 Rue du Faubourg Saint-Antoine, Paris, 75012, France.
A Cambon-BinderOrthopedics and Hand Surgery Department, Saint-Antoine Hospital, 184 Rue du Faubourg Saint-Antoine, Paris, 75012, France.
A SautetOrthopedics and Hand Surgery Department, Saint-Antoine Hospital, 184 Rue du Faubourg Saint-Antoine, Paris, 75012, France.
Sorbonne Université · FR

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeVolar locking plates, used in distal radius fracture (DRF), present a risk of injuring extensor tendons with screws penetrating the dorsal cortex of the radius. Actually, even when aiming to use maximum-length unicortical locking screws, some still could be bicortical. We hypothesize the use of only short unicortical screws would allow a proper stabilization of the radial epiphysis without the risk of dorsal cortex penetration. MATERIALS AND

methodsA prospective monocentric non-randomized study was conducted. Patients with DRF (excepted for partial dorsal joint fractures) were treated in group A with short locking epiphyseal screws (16 mm for females, 18 mm for males) and in group B with full-length unicortical locking screws. Ultrasound was done 3 months postoperatively to evaluate the number and length of prominent dorsal screws. X-rays were performed after 6 weeks to assess stability according to volar tilt and radial inclination variations.

resultsThere were 37 patients in group A and 39 in group B with 148 and 156 epiphyseal screws, respectively. In group A, there were 0% of dorsal penetrating screws against 6.5% (10 screws from 8 patients) in group B (p < 0.05). There was no significant difference for the stability between the groups: mean volar tilt variation ( - 0.6° vs. - 0.7°) and mean radial inclination variation ( - 0.4° vs. - 0.4°).

conclusionFor a same stability with volar locking plates for DRF, short epiphyseal locking screws should be preferred to full-length unicortical screws in order to prevent extensor tendon injuries. Based on 75% of distal radial average anteroposterior width for each sex, screw lengths of 16 mm for females and 18 mm for males seem to be the length to use. LEVEL OF EVIDENCE 2: Prospective, Comparisons made, non-randomized.

Indexed as

Radius FracturesBone PlatesBone ScrewsEpiphysesFemaleFracture Fixation, InternalHumansMaleProspective StudiesDistal radius fractureSecondary displacementShort screwStabilityTendon injury

Identifiers

PMID33661374
OpenAlexW3133857404

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.