Evidence map›Paper›PMID 33659080›Full record

ArticleBiomedical optics express2021

Lightsheet-based flow cytometer for whole blood with the ability for the magnetic retrieval of objects from the blood flow.

Roman A Verkhovskii, Anastasiia A Kozlova, Olga A Sindeeva, Ilya O Kozhevnikov, Ekaterina S Prikhozhdenko, Oksana A Mayorova, Oleg V Grishin, Mikhail A Makarkin, Alexey V Ermakov, Arkady S Abdurashitov and 2 more

Abstract read
In one paragraph

Article in Biomedical optics express, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 6 papers.

0numbers the graph read from it
0cells of the map it votes in
6citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

6 citing papers in PubMed.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Article
  6. Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

12 authors.

Roman A VerkhovskiiSaratov State University, 83 Astrakhanskaya str., Saratov 410012, Russia.
Anastasiia A KozlovaSaratov State University, 83 Astrakhanskaya str., Saratov 410012, Russia.
Olga A SindeevaSaratov State University, 83 Astrakhanskaya str., Saratov 410012, Russia.
Ilya O KozhevnikovSaratov State University, 83 Astrakhanskaya str., Saratov 410012, Russia.
Ekaterina S PrikhozhdenkoSaratov State University, 83 Astrakhanskaya str., Saratov 410012, Russia.
Oksana A MayorovaSaratov State University, 83 Astrakhanskaya str., Saratov 410012, Russia.ORCID https://orcid.org/0000-0002-6440-3947
Oleg V GrishinSaratov State University, 83 Astrakhanskaya str., Saratov 410012, Russia.
Mikhail A MakarkinSaratov State University, 83 Astrakhanskaya str., Saratov 410012, Russia.
Alexey V ErmakovSaratov State University, 83 Astrakhanskaya str., Saratov 410012, Russia.
Arkady S AbdurashitovSkolkovo Innovation Center, 3 Nobel str., Moscow 121205, Russia.ORCID https://orcid.org/0000-0003-0731-8364
Valery V TuchinSaratov State University, 83 Astrakhanskaya str., Saratov 410012, Russia.ORCID https://orcid.org/0000-0001-7479-2694
Daniil N BratashovSaratov State University, 83 Astrakhanskaya str., Saratov 410012, Russia.ORCID https://orcid.org/0000-0002-2096-4478

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

Detection and extraction of circulating tumor cells and other rare objects in the bloodstream are of great interest for modern diagnostics, but devices that can solve this problem for the whole blood volume of laboratory animals are still rare. Here we have developed SPIM-based lightsheet flow cytometer for the detection of fluorescently-labeled objects in whole blood. The bypass channel between two blood vessels connected with the external flow cell was used to visualize, detect, and magnetically separate fluorescently-labeled objects without hydrodynamic focusing. Carriers for targeted drug delivery were used as model objects to test the device performance. They were injected into the bloodstream of the rat, detected fluorescently, and then captured from the bloodstream by a magnetic separator prior to filtration in organs. Carriers extracted from the whole blood were studied by a number of

Identifiers

PMID33659080
PMCPMC7899519

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.