ArticleThe international journal of cardiovascular imaging2021
Feasibility of using a non-sedation protocol for evaluation of neonatal congenital heart disease by using a 16-cm wide-detector computed tomography with a low radiation dose: preliminary experience from a single pediatric medical center.
Article in The international journal of cardiovascular imaging, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 1 paper.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
1 citing paper in PubMed, 2 citations in OpenAlex.
- Developing Congenital Cardiac CT Services in Low-Resource Settings: A Quality Improvement Approach.Pediatric cardiology · 2026Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
12 authors at 2 institutions in 1 country.
Funding
Abstract
The aim of this study is to explore the feasibility of using a non-sedation protocol for the evaluation of neonatal congenital heart disease by using 16-cm wide-detector CT with a low radiation dose. Thirty-four neonates (group 1) were enrolled to undergo cardiac CT without sedation between August 2018 and March 2019. The control group (group 2) comprising 20 inpatient neonates was sedated. Cardiac CT was performed using 16-cm area detector 320-row CT with free breathing and prospective ECG-triggering scan mode. The examination completion time, radiation dose, and image quality were compared between the groups. The results of cardiac CT for patients in group 1 who underwent surgery were compared with surgical findings. Intergroup differences in body weight, age, examination completion time, radiation dose, and image quality evaluation were not significant. There was no significant difference in oxygen saturation before and after the examination in group 1. In all, 98 separate cardiovascular abnormalities in 27 group 1 patients were confirmed using surgical reports. The overall sensitivity, specificity, positive predictive value, and negative predictive value of cardiac CT were 94.90%, 100.0%, 100.0%, and 98.53%. The non-sedation protocol can be applied in neonates with congenital heart disease by using 16-cm wide-detector CT with a low radiation dose. Based on the image quality obtained, non-sedative examination did not extend the examination completion time and helped avoid the possible side effects of sedative drugs.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.