ArticleJournal of applied clinical medical physics2021
Reproducibility of a novel, vacuum-assisted immobilization for breast stereotactic radiotherapy.
Article in Journal of applied clinical medical physics, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 7 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
7 citing papers in PubMed, 5 citations in OpenAlex.
- Verifying calculated dose to the breast in stereotactic radiotherapy: A practical phantom-based method.Journal of applied clinical medical physics · 2026Article
- Multi-angle acquisition and 3D composite reconstruction for organ-targeted PET using planar detectors.Medical physics · 2025Article
- A Prospective Trial of Single-Fraction Radiation to the Tumor Bed with a Novel Breast-Specific Stereotactic Radiation Therapy Device: The GammaPod.Advances in radiation oncology · 2024Article
- Radiotherapy of early-stage breast cancer.Precision radiation oncology · 2023Review
- Correlation of treatment time to target volume for GammaPod treatments: A simple second calculation.Journal of applied clinical medical physics · 2022Article
- Workflow guide to delivering a safe breast treatment using a novel stereotactic radiation delivery system.Journal of radiosurgery and SBRT · 2021Article
- Development and validation of a comprehensive patient-specific quality assurance program for a novel stereotactic radiation delivery system for breast lesions.Journal of applied clinical medical physics · 2019Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
8 authors at 5 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
A novel, breast-specific stereotactic radiotherapy device has been developed for delivery of highly conformal, accelerated partial breast irradiation. This device employs a unique, vacuum-assisted, breast cup immobilization system that applies a gentle, negative pressure to the target breast with the patient in the prone position. A device-specific patient loader is utilized for simulation scanning and device docking. Prior to clinical activation, a prospective protocol enrolled 25 patients who had been or were to be treated with breast conservation surgery and adjuvant radiotherapy for localized breast cancer. The patients underwent breast cup placement and two separate CT simulation scans. Surgical clips within the breast were mapped and positions measured against the device's integrated stereotactic fiducial/coordinate system to confirm reproducible and durable immobilization during the simulation, treatment planning, and delivery process for the device. Of the enrolled 25 patients, 16 were deemed eligible for analysis. Seventy-three clips (median, 4; mean, 4.6; range, 1-8 per patient) were mapped in these selected patients on both the first and second CT scans. X, Y, and Z coordinates were determined for the center point of each clip. Length of vector change in position was determined for each clip between the two scans. The mean displacement of implanted clips was 1.90 mm (median, 1.47 mm; range, 0.44-6.52 mm) (95% CI, 1.6-2.20 mm). Additional analyses stratified clips by position within the breast and depth into the immobilization cup. Overall, this effort validated the clinically utilized 3-mm planning target volume margin for accurate, reliable, and precise employment of the device.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.