Influence of patient motion on quantitative accuracy in cardiac

Jonny Nordström, Hendrik J Harms, Tanja Kero, Jens Sörensen, Mark Lubberink

Open access · hybridAbstract read
In one paragraph

Article in Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology, 2022. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 3 papers.

0numbers the graph read from it
0cells of the map it votes in
3citing papers in PubMed
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

3 citing papers in PubMed, 8 citations in OpenAlex.

  1. Article
  2. Detection and correction of patient motion in dynamicJournal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Article
  3. Review of cardiovascular imaging in the Journal of Nuclear Cardiology 2022: positron emission tomography, computed tomography, and magnetic resonance.Journal of nuclear cardiology : official publication of the American Society of Nuclear Cardiology · 2023
    Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

5 authors at 1 institution in 3 countries.

Jonny NordströmDepartment of Surgical Sciences/Nuclear Medicine & PET, Uppsala University, Uppsala, Sweden. jonny.nordstrom@regiongavleborg.se.
Hendrik J HarmsDepartment of Surgical Sciences/Nuclear Medicine & PET, Uppsala University, Uppsala, Sweden.
Tanja KeroDepartment of Surgical Sciences/Nuclear Medicine & PET, Uppsala University, Uppsala, Sweden.
Jens SörensenDepartment of Surgical Sciences/Nuclear Medicine & PET, Uppsala University, Uppsala, Sweden.
Mark LubberinkDepartment of Surgical Sciences/Nuclear Medicine & PET, Uppsala University, Uppsala, Sweden.
Uppsala University · SE

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundPatient motion is a common problem during cardiac PET. The purpose of the present study was to investigate to what extent motions influence the quantitative accuracy of cardiac

methodFrequency and magnitude of motion was assessed visually using data from 50 clinical

resultsPatient motion was detected in 68% of clinical cases by visual inspection. All observed motions were small with amplitudes less than half the LV wall thickness. A clear pattern of motion influence was seen in the simulations with a decrease of myocardial blood flow (MBF) in the region of myocardium to where the motion was directed. The perfusable tissue fraction (PTF) trended in the opposite direction. Global absolute average deviation of MBF was 3.1% ± 1.8% and 7.3% ± 6.3% for motions with maximum amplitudes of 5 and 20 mm, respectively. Automated motion detection showed a sensitivity of 90% for simulated motions ≥ 10 mm but struggled with the smaller (≤ 5 mm) simulated (sensitivity 45%) and clinical motions (accuracy 48%).

conclusionPatient motion can impair the quantitative accuracy of MBF. However, at typically occurring levels of patient motion, effects are similar to or only slightly larger than inter-observer variability, and downstream clinical effects are likely negligible.

Indexed as

Coronary CirculationWaterHumansMotionOxygen RadioisotopesPositron-Emission TomographyPositron Emission Tomography Computed TomographyReproducibility of ResultsOxygen RadioisotopesWaterCADimage interpretationMyocardial blood flowPET