Observational studySupportive care in cancer : official journal of the Multinational Association of Supportive Care in Cancer2021
Continuous recording of vital signs with a wearable device in pediatric patients undergoing chemotherapy for cancer-an operational feasibility study.
Observational study in Supportive care in cancer : official journal of the Multinational Association of Supportive Care in Cancer, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. It is linked to trial NCT04134429 (Continuous Monitoring of Health Data With a Wearable Device in Pediatric Patients Undergoing Chemotherapy for Cancer - a Feasibility Pilot Study), which is not on this map. Cited by 14 papers.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Continuous Monitoring of Health Data With a Wearable Device in Pediatric Patients Undergoing Chemotherapy for Cancer - a Feasibility Pilot Study
Who cites it
14 citing papers in PubMed, 20 citations in OpenAlex.
- Continuous Temperature Monitoring via Wearable Devices for Fever or Infection Management in Acute Care Hospitals: Scoping Review of Clinical Implementation and Data Analytics.JMIR mHealth and uHealth · 2026Article
- Integration of Artificial Intelligence and Wearable Devices in Pediatric Clinical Care: A Review.Bioengineering (Basel, Switzerland) · 2025Review
- Scoping review of the utilization of wearable devices in pediatric and young adult oncology.NPJ digital medicine · 2025Article
- Wearable biosensors for pediatric hospitals: a scoping review.Pediatric research · 2025Article
- Vital signs continuously monitored by two wearable devices in pediatric oncology patients, NCT04914702.Scientific data · 2025Observational
- The Measurement of Vital Signs in Pediatric Patients by Lifelight Software in Comparison to the Standard of Care: Protocol for the VISION-Junior Observational Study.JMIR research protocols · 2025Observational
- Continuous timely monitoring of core temperature with two wearable devices in pediatric patients undergoing chemotherapy for cancer - a comparison study.Supportive care in cancer : official journal of the Multinational Association of Supportive Care in Cancer · 2024Observational
- Artificial Intelligence and Its Revolutionary Role in Physical and Mental Rehabilitation: A Review of Recent Advancements.BioMed research international · 2024Review
- The Impact of Heart Rate Variability Monitoring on Preventing Severe Cardiovascular Events.Diagnostics (Basel, Switzerland) · 2023Review
- Wireless monitoring devices in hospitalized children: a scoping review.European journal of pediatrics · 2023Article
- Wearable Devices for Remote Monitoring of Heart Rate and Heart Rate Variability-What We Know and What Is Coming.Sensors (Basel, Switzerland) · 2022Review
- High-frequency temperature monitoring at home using a wearable device: A case series of early fever detection and antibiotic administration for febrile neutropenia with bacteremia.Pediatric blood & cancer · 2022Article
- Vital signs in pediatric oncology patients assessed by continuous recording with a wearable device, NCT04134429.Scientific data · 2022Observational
- Review
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
5 authors at 1 institution in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
purposePediatric patients with cancer are at high risk for severe infections. Infections can trigger changes of vital signs long before clinical symptoms arise. Continuous recording may detect such changes earlier than discrete measurements. We aimed to assess the feasibility of continuous recording of vital signs by a wearable device (WD) in pediatric patients undergoing chemotherapy for cancer.
methodsIn this prospective, observational single-center study, pediatric patients under chemotherapy wore the Everion® WD for 14 days. The predefined patient-specific goal was heart rate recorded in good quality during ≥18/24 h per day, on ≥7 consecutive days. The predefined criterion to claim feasibility was ≥15/20 patients fulfilling this patient-specific goal.
resultsTwenty patients were included (median age, 6 years; range, 2-16). Six patients aged 3-16 years fulfilled the patient-specific goal. Quality of heart rate recording was good during 3992 of 6576 (61%) hours studied and poor during 300 (5%) hours, and no data was recorded during 2284 (35%) hours. Eighteen of 20 participants indicated that this WD is acceptable to measure vital signs in children under chemotherapy.
conclusionThe predefined feasibility criterion was not fulfilled. This was mainly due to important compliance problems and independent of the WD itself. However, continuous recording of vital signs was possible across a very wide age range in pediatric patients undergoing chemotherapy for cancer. We recommend to study feasibility in the Everion® again, plus in further WDs, applying measures to enhance compliance.
trial registrationClinicalTrials.gov (NCT04134429) on October 22, 2019.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials