Evidence map›Paper›PMID 33654669›Full record

ArticleQuantitative imaging in medicine and surgery2021

Improving sensitivity and imaging depth of ultrasound-switchable fluorescence via an EMCCD-gain-controlled system and a liposome-based contrast agent.

Tingfeng Yao, Yang Liu, Liqin Ren, Baohong Yuan

Open access · diamondAbstract read
In one paragraph

Article in Quantitative imaging in medicine and surgery, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 9 papers.

0numbers the graph read from it
0cells of the map it votes in
9citing papers in PubMed
0.6field-weighted citation impact, top 35% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

9 citing papers in PubMed, 10 citations in OpenAlex.

  1. Article
  2. Article
  3. Article
  4. Article
  5. Nano research · 2023
    Article
  6. Article
  7. Article
  8. Review
  9. Thermo- and pH-sensitive nanoparticles of poly (Experimental biology and medicine (Maywood, N.J.) · 2022
    Article
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

4 authors at 2 institutions in 1 country.

Tingfeng YaoUltrasound and Optical Imaging Laboratory, Department of Bioengineering, The University of Texas at Arlington, Arlington, TX, USA.
Yang LiuUltrasound and Optical Imaging Laboratory, Department of Bioengineering, The University of Texas at Arlington, Arlington, TX, USA.
Liqin RenUltrasound and Optical Imaging Laboratory, Department of Bioengineering, The University of Texas at Arlington, Arlington, TX, USA.
Baohong YuanUltrasound and Optical Imaging Laboratory, Department of Bioengineering, The University of Texas at Arlington, Arlington, TX, USA.
The University of Texas at Arlington · USThe University of Texas Southwestern Medical Center · US

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

backgroundThe ultrasound-switchable fluorescence (USF) technique was recently developed to achieve high-resolution fluorescence imaging in centimeters-deep tissue. This study introduced strategies to significantly improve imaging sensitivity and depth using an electron multiplying charge-coupled device (EMCCD) camera-based USF imaging system and a newly developed USF contrast agent of indocyanine green (ICG)-encapsulated liposomes. For a quantitative study, a phantom of a sub-millimeter silicone tube embedded in centimeter-thick chicken breast tissue was adopted in this study as a model.

methodsThe synthesized ICG-liposome was characterized and compared with the previously reported ICG-nanogel. The exposure of the EMCCD camera was controlled via the MATLAB (The MathWorks, Inc. USA), instead of an external hardware trigger. The stability of the electron multiplying (EM) gain of the EMCCD camera was compared between two trigger modes: the MATLAB trigger mode and the external hardware trigger mode. The signal-to-noise ratio (SNR) of the USF imaging with different EM gain in various thick tissue was studied.

resultsThe hydrodynamic size of the ICG-liposome was ~181 nm. The ICG-liposome had a sharper temperature switching curve and a better USF performance than the previously reported ICG-nanogel. The EM gain was more stable in MATLAB trigger mode than the external hardware trigger mode. Although, as usual, the SNR decreased quickly with the increase of the tissue thickness, the proposed strategies improved the SNR and the imaging depth significantly by adopting the novel contrast agent and controlling the EM gain.

conclusionsWe successfully imaged the sub-millimeter silicone tube with an inner diameter of 0.76 mm and an outer diameter of 1.65 mm in 5.5 cm-thick chicken breast tissue using 808 nm excitation light with a low intensity of 28.35 mW/cm

Indexed as

deep tissue imaginghigh resolutionIndocyanine green (ICG)liposomenear-infrared (NIR)ultrasound-switchable fluorescence (USF)

Identifiers

PMID33654669
PMCPMC7829175
OpenAlexW3094850807

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.