Trial reportScientific reports2021
A novel device for detecting anaerobic threshold using sweat lactate during exercise.
Trial report in Scientific reports, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 37 papers, 1 of them a synthesis that pooled it.
What it found
Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.
The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.
The trial behind it
Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.
Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.
Who cites it
37 citing papers in PubMed, 1 synthesis or guideline pooled it, 67 citations in OpenAlex.
- The global scientific evolution of cardiopulmonary performance and threshold research in sports sciences during 2010-2025: a comparative bibliometric analysis based on web of science and scopus.Frontiers in research metrics and analytics · 2026Pooled it
- Sweat lactate sensor for detecting anaerobic threshold in heart failure: a prospective clinical trial (LacS-001).Scientific reports · 2024Trial
- A mechanically robust wearable sweat analysis platform with plug-and-play interconnects for continuous biomarker profiling.Microsystems & nanoengineering · 2026Article
- Quantitative assessment of gait alterations and variability in sulky-driven Standardbred trotters after a standardised exercise test.Equine veterinary journal · 2026Article
- Continuous assessment of the sweat rate-lactate content association during acetylcholine-induced sweating: an exploratory study.European journal of applied physiology · 2026Article
- Seamless human electronics interfacing through advanced skin attachable and implantable sensor technologies.Discover nano · 2026Review
- Validation of aerobic threshold assessment using a sweat lactate sensor during arm crank exercise by healthy adults.Physiological reports · 2026Article
- Minimally invasive prediction of blood lactate during incremental exercise via heart rate, core body temperature, and sweat-derived indices.Scientific reports · 2026Article
- From lab to field: progress and prospect of sweat sensing technology in sports monitoring.Mikrochimica acta · 2026Review
- Body Biofluids for Minimally-Invasive Diagnostics: Insights, Challenges, Emerging Technologies, and Clinical Potential.Advanced healthcare materials · 2026Review
- A Novel Method to Determine the Respiratory Compensation Point from Percutaneous Oxygen Saturation of Healthy Adults During a Ramp-Incremental Test: A Cross-Sectional Study.Medical sciences (Basel, Switzerland) · 2025Article
- Feasibility study of a novel wearable sweat sensor for anaerobic threshold determination.Scientific reports · 2025Article
- All-in-One Sustainable Thread Biosensor for Chemiluminescence Smartphone Detection of Lactate in Sweat.Biosensors · 2025Article
- Simultaneous Remote Non-Invasive Blood Glucose and Lactate Measurements by Mid-Infrared Passive Spectroscopic Imaging.Sensors (Basel, Switzerland) · 2025Article
- Advanced Wearable Devices for Monitoring Sweat Biochemical Markers in Athletic Performance: A Comprehensive Review.Biosensors · 2024Review
- A Simple and Sensitive Wearable SERS Sensor Utilizing Plasmonic-Active Gold Nanostars.ACS omega · 2024Article
- Lactate threshold evaluation in swimming using a sweat lactate sensor: A prospective study.European journal of sport science · 2024Article
- Differential patterns of sweat and blood lactate concentration response during incremental exercise in varied ambient temperatures: A pilot study.Temperature (Austin, Tex.) · 2024Article
- Wearable device for continuous sweat lactate monitoring in sports: a narrative review.Frontiers in physiology · 2024Review
- Anaerobic threshold using sweat lactate sensor under hypoxia.Scientific reports · 2023Article
Corrections and comments
PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.
Authors and funding
14 authors at 3 institutions in 1 country.
Funding
No grant is acknowledged in the PubMed record.
Abstract
The lactate threshold (LT1), which is defined as the first rise in lactate concentration during incremental exercise, has not been non-invasively and conveniently determined in a clinical setting. We aimed to visualize changes in lactate concentration in sweat during exercise using our wearable lactate sensor and investigate the relationship between the lactate threshold (LT1) and ventilatory threshold (VT1). Twenty-three healthy subjects and 42 patients with cardiovascular diseases (CVDs) were enrolled. During exercise, the dynamic changes in lactate values in sweat were visualized in real-time with a sharp continuous increase up to volitional exhaustion and a gradual decrease during the recovery period. The LT1 in sweat was well correlated with the LT1 in blood and the VT1 (r = 0.92 and 0.71, respectively). In addition, the Bland-Altman plot described no bias between the mean values (mean differences: - 4.5 and 2.5 W, respectively). Continuous monitoring of lactate concentrations during exercise can provide additional information for detecting the VT1.
Indexed as
Identifiers
What OpenQuestion holds
Registered trials
Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.