Evidence map›Paper›PMID 33653630›Full record

ArticleThe Journal of arthroplasty2021

Is Combined Anteversion Equally Affected by Acetabular Cup and Femoral Stem Anteversion?

Aidin Eslam Pour, Ran Schwarzkopf, Kunj Pareshkumar Patel, Manan Anjaria, Jean Yves Lazennec, Lawrence D Dorr

Abstract read
In one paragraph

Article in The Journal of arthroplasty, 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Cited by 11 papers.

0numbers the graph read from it
0cells of the map it votes in
11citing papers in PubMed
–field-weighted citation impact
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

11 citing papers in PubMed.

  1. Article
  2. Review
  3. Article
  4. Article
  5. Article
  6. Article
  7. Article
  8. Article
  9. Article
  10. Article
  11. Review
4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

6 authors.

Aidin Eslam PourDepartment of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI.
Ran SchwarzkopfDepartment of Orthopaedic Surgery, New York University, New York, NY.
Kunj Pareshkumar PatelDepartment of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI.
Manan AnjariaDepartment of Orthopaedic Surgery, University of Michigan, Ann Arbor, MI.
Jean Yves LazennecDepartment of Orthopaedic and Trauma Surgery, Pitié-Salpétrière Hospital Assistance Publique-Hopitaux de Paris, UPMC, Paris, France.
Lawrence D DorrDorr Institute for Arthritis Research and Education, Los Angeles, CA.

Funding

Personal Surgical Planning to Avoid Hip Dislocation after Total Hip Arthroplasty: Concept of Functional Safe Zone.K08AR073933 · NIAMS · YALE UNIVERSITY · PI ESLAM POUR, AIDIN · 2019 to 2023
$827k
NIAMS NIH HHS K08 AR073933
6 · The paper itself

Abstract

backgroundTo create a safe zone, an understanding of the combined femoral and acetabular mating during hip motion is required. We investigated the position of the femoral head inside the acetabular liner during simulated hip motion. We hypothesized that cup and stem anteversions do not equally affect hip motion and combined hip anteversion.

methodsHip implant motion was simulated in standing, sitting, sit-to-stand, bending forward, squatting, and pivoting positions using the MATLAB software. A line passing through the center of the stem neck and the center of the prosthetic head exits at the polar axis (PA) of the prosthetic head. When the prosthetic head and liner are parallel, the PA faces the center of the liner (PA position = 0, 0). By simulating hip motion in 1-degree increments, the maximum distance of the PA from the liner center and the direction of its movement were measured (polar coordination system).

resultsThe effect of modifying cup and stem anteversion on the direction and distance of the PA's change inside the acetabular liner was different. Stem anteversion influenced the PA position inside the liner more than cup anteversion during sitting, sit-to-stand, squatting, and bending forward (P = .0001). This effect was evident even when comparing stems with different neck angles (P = .0001).

conclusionCup anteversion, stem anteversion, and stem neck-shaft angle affected the PA position inside the liner and combined anteversion in different ways. Thus, focusing on cup orientation alone when assessing hip motion during different daily activities is inadequate.

Indexed as

Arthroplasty, Replacement, HipHip ProsthesisAcetabulumFemurHumansRange of Motion, Articularacetabular implant anteversioncombined anteversionfemoral stem anteversionhip-spine relationsagittal pelvic tilttotal hip arthroplasty

Identifiers

PMID33653630
PMCPMC8197737

What OpenQuestion holds

Textmetadata
LicenceTDM
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.