Evidence map›Paper›PMID 33651239›Full record

ArticleJournal of medical ultrasonics (2001)2021

Normal values of combinational elastography in adult liver: the influence of age.

Yoko Idobe-Fujii, Ryoko Omoso, Shinya Fujii, Hiromitsu Fujiwara, Yuki Nakamura, Takahiro Nomi, Yuichiro Sasaki, Hiroyuki Sasaki, Hajime Isomoto, Yoshikazu Murawaki

Abstract read
PubMed Publisher
In one paragraph

Article in Journal of medical ultrasonics (2001), 2021. The graph could read no effect estimate from its abstract, so it casts no vote on the map. Not yet cited in PubMed.

0numbers the graph read from it
0cells of the map it votes in
0citing papers in PubMed
–field-weighted citation impact, top 97% of its field
1 · What the graph read from it

What it found

Each row is one number read from the abstract, on the scale the paper reported it, with its interval. Left of the dashed line favours the treatment, right favours the comparator. Under each row is the sentence it came from. New to these charts? A ten-minute tutorial.

The abstract states no effect estimate the extractor could read, or names no intervention and outcome on the map, so this paper lights no cell and moves no belief. It is still indexed, cited and linked below.

2 · The registry

The trial behind it

Trials whose registry record cites this paper, or whose number appears in the abstract. A trial that started after this paper was published is citing it as background, not reporting it.

Neither the registry nor the abstract names a trial number. If this is a trial report, that itself is worth knowing.

3 · Its place in the literature

Who cites it

0 citing papers in PubMed, 0 citations in OpenAlex.

No citing paper in PubMed yet.

4 · The record

Corrections and comments

PubMed lists nothing against this paper. Absence here is not a guarantee, only a check that was made.

5 · Who and what money

Authors and funding

10 authors at 1 institution in 1 country.

Yoko Idobe-FujiiCheckup Center, Saiseikai Sakaiminato General Hospital, 44 Yonegawa-cho, Sakaiminato, Tottori, 684-8555, Japan. yok.fujii@sakaiminato-saiseikai.jp.
Ryoko OmosoClinical Laboratory, Saiseikai Sakaiminato General Hospital, Tottori, Japan.
Shinya FujiiDivision of Radiology, Department of Multidisciplinary Internal Medicine, Tottori University Faculty of Medicine, Tottori, Japan.
Hiromitsu FujiwaraClinical Laboratory, Saiseikai Sakaiminato General Hospital, Tottori, Japan.
Yuki NakamuraDepartment of Gastroenterology, Saiseikai Sakaiminato General Hospital, Tottori, Japan.
Takahiro NomiDepartment of Gastroenterology, Saiseikai Sakaiminato General Hospital, Tottori, Japan.
Yuichiro SasakiDepartment of Gastroenterology, Saiseikai Sakaiminato General Hospital, Tottori, Japan.
Hiroyuki SasakiCheckup Center, Saiseikai Sakaiminato General Hospital, 44 Yonegawa-cho, Sakaiminato, Tottori, 684-8555, Japan.
Hajime IsomotoDivision of Gastroenterology and Nephrology, Department of Multidisciplinary Internal Medicine, Tottori University Faculty of Medicine, Tottori, Japan.
Yoshikazu MurawakiDepartment of Gastroenterology, Saiseikai Sakaiminato General Hospital, Tottori, Japan.
Tottori University · JP

Funding

No grant is acknowledged in the PubMed record.

6 · The paper itself

Abstract

purposeWe aimed to clarify the normal values obtained by simultaneous use of shear wave imaging and strain imaging (combinational elastography) in liver and reveal how aging influences them.

methodsIn our checkup center, 257 examinees were diagnosed with normal liver based on questionnaires about liver disease and their drinking history, liver function test results, and ultrasound B-mode study findings. We estimated the values of combinational elastography and considered the correlation between the values and age. A multivariate analysis was performed concerning several features and the liver fibrosis (LF) index. We divided examinees into a younger group (< 65 years old) and an older group (≥ 65 years old), and assessed the effect of age on the LF index.

resultsThe mean shear wave velocity (Vs) of shear wave measurement (SWM) was 1.10 ± 0.17 m/s (range 0.84-1.93), and the mean LF index of real-time tissue elastography (RTE) was 1.371 ± 0.458 (range 0.258-3.173). There was no significant correlation between Vs and age. However, the LF index increased significantly with age. The multivariate analysis showed that age (P < 0.001) and BMI (P < 0.05) significantly affected the LF index. Indeed, the LF index in the older group was significantly higher than that in the younger group (P < 0.001).

conclusionIn adult liver, the normal Vs of SWM was 1.10 ± 0.17 m/s, and the normal LF index of RTE was 1.371 ± 0.458. The LF index increased significantly with age in contrast to Vs; therefore, the influence of age should be considered when using combinational elastography.

Indexed as

AdultAgedAge FactorsAgingElasticity Imaging TechniquesFemaleHumansLiverMaleMiddle AgedReference ValuesLiver fibrosis indexRTEShear wave imagingStrain imagingUltrasound elastography

Identifiers

PMID33651239
OpenAlexW3135344961

What OpenQuestion holds

Textmetadata
Read underepoch 390

Registered trials

None linked

Read under generation 80e0d062 · epoch 390. Bibliography from PubMed, PubMed Central and OpenAlex; grants from NIH RePORTER; trial links from ClinicalTrials.gov; estimates, votes and beliefs from the OpenQuestion graph.